Authorisation Via The Enable Input - Mennekes AMTRON Compact 2.0 11 Operating And Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 33
Electrical connection of the switching contact
ATTENTION
Material damage due to improper installation
Improper installation of the switching contact can
damage the product or lead to malfunctions. Ob-
serve the following requirements during the install-
ation:
u Select suitable cable routing to avoid interfer-
ence.
In the delivery state, a jumper is inserted on the
downgrade input. This must be removed first.
Fig. 11: Removing the jumper
u Remove the jumper.
12 V DC, 8 mA
Downgrade input
Fig. 12: Schematic circuit diagram: Connection of an
external switching contact (default setting: NC)
u Install external switching contact.
u Strip the cable.
u Strip the conductors 10 mm.
u Connect the conductors to terminals 3 and 4
(XG1).
u Comply with the connection data for the down-
grade input.
1 "4 Technical data" [} 10]
XG1
3
NC
NO
4
Configuration
The reduced charging current, which is applied
when the switching contact at the downgrade input
is energised, can be set via DIP switches 4 and 5
on bank S2. The charging current is reduced on a
percentage basis depending on the set maximum
charging current.
DIP switch
Percent-
setting (bank
age of
S2)
max. char-
ging cur-
4
5
rent
OFF
OFF
0 %
OFF
ON
25 %
ON
OFF
50 %
ON
ON
75 %
* At least 6 A are always available for the charging
process. If the calculated reduced charge current is
less than 6 A, it is rounded up.

6.2.2 Authorisation via the enable input

The tasks described in this section may only
be carried out by a qualified electrician.
The product contains an enable input for author-
ising the charging process. A switching contact
must be installed externally and connected to the
enable input for this purpose. The switching contact
can be a key switch (continuous signal) or a push-
button (pulse signal), for example.
Continuous signal (default setting):
Switching contact
status
open
closed
Reduced charging
current (example:
max. charging cur-
rent = 10 A)
0 A
6 A *
6 A *
7.5 A *
Authorisation status
Authorisation has not
occurred
Authorisation is taking
place
EN