Technical data

AMTRON® Compact 2.0 7,4
Max. charging power [kW]
Connection
Rated current I
 [A]
nA
Rated current of a charging point Mode 3 I
Rated voltage U
[V] AC ±10 %
N
Rated frequency f
 [Hz]
N
Max. back-up fuse [A]
Rated insulation voltage U
Rated impulse withstand voltage U
Conditional rated short-circuit current I
Rated diversity factor RDF
System according to type of earth connection
EMC classification
Protection class
IP rating
Overvoltage category
Mechanical impact protection
Contamination rating
Installation
Stationary / movable
Use (according to IEC 61439-7)
External design
Dimensions H x W x D [mm]
Weight [kg]
Standard
* For the design of the maximum back-up fuse, the regulations applicable at the installation site must be
observed.
The specific standards according to which the product was tested can be found in the declaration of con-
formity for the product. The declaration of conformity can be found on our website in the download section
for the selected product.
[A]
nC
[V]
i
[kV]
imp
[kA]
cc
7.4
single phase
32
32
230
50
40 *
500
4
1.8
1
TN / TT (IT under certain conditions)
A+B
I
IP 44
III
IK10
3
Outdoor or indoor
Stationary
AEVCS
Wall mounted
360.5 x 206.9 x 145.6
5.1
IEC 61851, IEC 61439-7
EN