Technical Data; General Data; Maximum Cable Cross-Sections At Terminals; Ambient Conditions - Mennekes AMTRON Start Manual

Charging station for electric vehicles
Hide thumbs Also See for AMTRON Start:
Table of Contents

Advertisement

4 Technical Data

4.1 General data

3.7 kW
Nominal voltage
230 / 400 V AC ±10 %
Nominal
50 Hz
frequency
Nominal current
16 A
Maximum back-
according to name plate /
up fuse
configuration
Charging power
3.7 kW
Mode 3
Max. charging
16 A,
current
single-
Mode 3
phase
Protection class
IP 44 (with permanently attached
charging cable or charging socket Type
2 with shutter)
IP 54 (with charging socket Type 2)
Protection class
I
Overvoltage
CAT III according to EN60664-1
category
Dimensions
474.8 mm x 259.2 mm x 220.1 mm
(H x W x D)
Weight
5 to 8.5 kg (depending on version)

4.1.1 Maximum cable cross-sections at terminals

rigid
3.7 kW
3 x 6 mm²
3 x 10 mm²
7.4 kW
5 x 6 mm²
11 kW
22 kW
5 x 10 mm²
Refer to special instructions on charging stations without
integrated circuit breaker (EU variants) in Chapter 5.5.2
"Safeguarding and personal protection" on page 13!
9
7.4 kW
11 kW
22 kW
32 A
16 A
32 A
7.4 kW
11 kW
22 kW
32 A,
16 A,
32 A,
single-
three-
three-
phase
phase
phase
flexible
3 x 4 mm²
3 x 6 mm²
5 x 4 mm²
5 x 6 mm²

4.2 Ambient conditions

Ambient temperature
Average temperature
over 24 hours
Storage temperature
Altitude
Relative humidity
-25 to +40 °C
< 35 °C
-25 to +40 °C
max. 2,000 metres above
sea level
max. 95 % (non-
condensing)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amtron standard eAmtron basicAmtron proAmtron basic eAmtron basic rAmtron light

Table of Contents