CD Automation Revo Revex RX3 Series User Manual page 49

Table of Contents

Advertisement

REVEX
3PH from 120A to 210A
10.6.5 MSG view
Message view shows the communication activity between the
computer and the power controller.
PORT
COM: use this view to see when the COM port is accessed
and its settings
MODBUS: Modbus communication protocol area
Area: use this view to see parameters being polled
READ
READ Area -> En
Log: enable a short read communication
log activity
READ Area -> En
Detail: if En Log enabled enable a detailed
read communication log activity
READ Area -> Only
Error: if En Log enabled enable a read
communication log activity only if in error
WRITE
Area: use this view to see which parameters and values are sent to the power control
READ Area -> En
Log: enable a write communication log activity
Log
Msg: use this view to see the "Data Log" protocol detail when Data Log window is active
Status: view the status and settings of the COM port
SYSTEM
Memory: view the memory usage of the Confi gurator software on the computer
10.6.6 Settings window
Use this window to choose user-settable options for the
Confi gurator software.
Language:
Languages: choose the language used in the
Available
software
NOTE! to activate the language change, you need to
close and open again the Confi gurator software
Serial
Port: Set the serial port parameter
Test: click to test for communication with a power
controller via the selected port
Port: select the computer's COM port to use to
communicate with power controllers
Baud
rate: select Auto to allow the Confi gurator to set
the baud rate for the COM port or deselect the option to
manually set the baud rate.
Options: Set the confi gurator options
List
Options: set whether or not parameter values are displayed in hexadecimal in simple view recipes
Directory: set the directories in which recipes and images are saved
Disable Check
Type: set to allow communication with power controllers that are not precise matches for
the supported types. Used only for special version. Note that set is not memorized after software shutdown
View:
Hide Tool
Bar: future use
Hide Status
Bar: select to hide the status bar that appears at the bottom of the program window
Instruments: Hide or show the available instrument in the left side of main windows
Show
All manuals and user guides at all-guides.com
49
User's manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Revo Revex RX3 Series and is the answer not in the manual?

Questions and answers

Table of Contents