:OPERation:ENABle

Parameters
Comments
Example

SYSTem

Subsystem Syntax

:ERRor?

Comments
56 HP E1364A Form C Switch Command Reference
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
STATus:OPERation:ENABle < number >
Register to set a bit in the Status Register. For the Form C Switch, when bit
8 in the Operation Status Register is set to 1, bit 7 in the Status Register is
set to 1.
Parameter Name
Parameter Type
< number >
numeric
Setting Bit 7 of the Status Register: STATus:OPERation:ENABle
256 sets bit 7 of the Status Register to 1 after bit 8 of the Operation
Status Register is set to 1.
Related Commands: [ROUTe:]SCAN
Enabling Status Register Bit 7:
STAT:OPER:ENAB 256
The SYSTem subsystem returns the error numbers and error messages in
the error queue of a switchbox, and returns the types and descriptions of
modules (cards) in a switchbox.
SYSTem
:ERRor?
:CDEScription? < number >
:CTYPe? < number >
:CPON < number > |ALL
SYSTem:ERRor?
returns the error numbers and corresponding error
messages in the error queue of a switchbox. See Appendix C for a listing of
some switchbox error numbers and messages.
Error Numbers/Messages in the Error Queue: Each error
generated by a switchbox stores an error number and corresponding
error message in the error queue. The error message can be up to 255
characters long.
Clearing the Error Queue: An error number/message is removed
from the queue each time the SYSTem:ERRor? command is sent.
The errors are cleared first-in, first-out. When the queue is empty,
each following SYSTem:ERRor? command returns 0, "No error". To
clear all error numbers/messages in the queue, execute the *CLS
command.
enables the Operation Status
Range of Values
1 - 32767
Enables bit 7 of Status Register