4 INSTALLATION
Recommended fuse sizes and minimum cable areas
Mig U5000i
Main voltage
Main cable area, CU/AWG (mm
Phase current, I RMS
Fuse, Time Delay
NOTE!
Sizes per National Electric Code for 90°C rated copper conductors @ 30°C ambient.
Not more than three conductors in raceway or cable. Local codes should be
followed if they specify larger sizes other than those listed above.
4.4

Terminating resistor

In order to avoid communication interference, the ends of the
CAN bus must have terminating resistors.
One end of the CAN bus is at the control panel, which has an
integral terminating resistor. The other end at the power
source must have a terminating resistor, as shown on the
right.
4.5

Connection of multiple wire feed units

With control unit and wire feed units without control panel (M0), you can manage up to 4 wire
feed units from one power source.
You can choose between the following connections:
1 GTAW (TIG) torch and 1 GMAW (MIG/MAG) gun (Universal power source required)
2 GMAW (MIG/MAG) guns
1 GTAW (TIG) torch and 3 GMAW (MIG/MAG) guns (Universal power source required)
4 GMAW (MIG/MAG) guns
When welding with water-cooled GMAW guns on all wire feed units, it is recommended to
connect a separate cooling unit for the two extra guns.
We recommend connecting the guns in parallel.
0459 087 887
Check that the unit is connected to the correct main supply voltage,
and that it is protected by the correct fuse sizes. A protective ground
connection must be made, in accordance with regulations.
Rating plate with supply connection data
2
)
- 15 -
460 V 3~ 60 Hz
460 V
10(6)
24 A
25 A
© ESAB AB 2019