Summer Mode, Hot Water Only (Rd 532 Appliances); Frost Protection (Rd 532 Appliances) - Benchmark ZWB 7-29 CC1 Installation And Servicing

Table of Contents

Advertisement

Operating the Appliance
ECO mode with demand detection, button is lit
The demand detection function enables maximum gas and water
economy.
Briefly turning a hot water tap on and then off again signals
demand to the appliance which then heats up the water to the set
temperature.
Hot water is thus available in about 1 minute.
ECO mode, button is lit
Water is not heated up until hot water is drawn. This means that
there is a longer waiting period before hot water is available.
3.6
Summer Mode, Hot Water Only
(RD 532 Appliances)
With room thermostat
B Turn temperature control
as far as the stop.
The central heating is now turned off. The hot water function
and the mains power supply for the heating programmer and
timer remain switched on.
3.7

Frost protection (RD 532 Appliances)

B Leave master switch switched on.
If the appliance is to be left for long periods switch the central
heating off:
B Add a suitable anti-freeze fluid to the water in the central heat-
ing system.
Suitable products are available from Betz-Dearborn Tel.: 0151
4209563, Fernox Tel.: 01799 550811 and Salamander on
0121 378 0952.