Appliances With Optional Plug-In Diverter Valve: Setting Hot Water Temperature; Frost Protection; Pump Anti-Seize Function; Fault Condition - Benchmark ZB 7-28 R 28 HE Installation And Servicing Instructions

Wall mounted condensing boiler for central heating
Hide thumbs Also See for ZB 7-28 R 28 HE:
Table of Contents

Advertisement

Commissioning
5.5
Appliances with optional plug-in
diverter valve: Setting hot water
temperature
B Do not set the temperature higher than
60°C for normal operation.
B Only use temperatures of up to 70°C
temporarily for thermal disinfection pur-
poses.
B Set the hot water temperature by means of the tem-
perature control
on the appliance.
6 720 610 333-07.1O
Fig. 36
Control Setting
Anti-clockwise limit
!
Clockwise limit
Table 11
ECO button
Pressing and holding the ECO button
Comfort mode to ECO-mode.
Comfort mode, ECO button is not lit (factory set-
ting)
Comfort mode the hot water tank has priority. The hot
water cylinder is first heated up to the set temperature.
The appliance then switches to central heating mode.
ECO mode, button is lit
In ECO mode the appliance switches between central
heating mode and cylinder charging mode every
12 minutes.
26
Water Temperature
approx. 10°C

(frost protection)

approx. 60°C
approx. 70°C
switches from
5.6
Frost protection
The appliance has an in-built frost protection device
which is generally suitable for most applications.
B Leave master switch switched on.
If the appliance is to be left for long periods switch the
central heating off:
B Add a suitable anti-freeze fluid to the water in the
central heating system.
Suitable products are available from Betz-Dearborn
Tel: 0151-4209563 and Fernox Tel: 01799-
550811.
5.7

Pump anti-seize function

This function prevents the central heating
i
pump seizing after long periods of inactiv-
ity.
Every time the pump is switched off, a timer is started.
If after 24 hours the pump has not run again, it is
switched on for a period of 5 minutes.
5.8

Fault Condition

A list of faults that may occur is given on
i
page 42.
In the unlikely event of a fault occurring while the appli-
ance is in operation:
The display then shows a fault code and the button
may also flash.
If the button
flashes:
B Press and hold the button
"– –".
The appliance will then start up again and the display
will show the central heating flow temperature.
If the button
does not flash:
B Switch the appliance off and then on again at the
master switch.
The appliance will start up again and the central heat-
ing flow temperature will be displayed.
until the display shows
6 720 611 443 GB (05.04)

Advertisement

Table of Contents
loading

Table of Contents