Installation of the flue

The standard 100 mm diameter horizontal flue system
is suitable for lengths upto 4 m.
Flues upto 650 mm do not require an extension duct
assembly.
Flues between 1600 mm and 4000 mm require exten-
sion duct assemblies.
NOTE: Flue lengths between 650 mm and 730 mm
cannot be accomodated. Refer to Fig. 17, 18, 19.
Standard system comprise: Flue turret - Flue turret
clamp - Terminal assembly - Wall sealing - plates.
Extension kit comprises: Air duct - Flue duct - Duct
clamp. Refer to Fig. 20.
Instructions for fitting other flue systems are packed
with the relevant flue kit.