Values that can only be read:
Description
.1
Heating outlet temperature.
.2
Sanitary outlet temperature.
.3
Heat store NTC sensor (ZSB.)
.4
Constant hot water NTC sensor (ZWB.)
1.2
Order no. for code plug: 8 714 411 XXX
1.4
Temperature voltage signal (Terminal 2) from room thermostat
(eg. TRQ 21, TR 100)
1.5
Specified CH flow temperature from programmer
1.6
Outside temperature from TA 211 E or room temperature from
TR 212 E
1.7
Status TR 2 (0 = Not present 1 = Frost protection 3 = Auto 4 = Day,
Night 5=Error)
1.8
Terminal 2 on programmer interface module
1.9
Identification code for the external module:
0, 2, 4, 5 = no module connected,
3 = ADM, 6 = TA 211E, 53 = ADM, 56 = TR 212 E).
2.9
Instantaneous power.
3.0
Fan speed
3.3
Quality of the ionisation signal:
0 = no ionisation,
1 = weak ionisation,
2 = medium ionisation,
3 = high ionisation.
3.6
Software version
Table 2 First Service Level; Values that can only be read
7 181 465 346 GB (03.02)
Bosch Heatronic board functions
Display
Reset Value
0 - 99˚C
-
0 - 99˚C
-
0 - 99˚C
0 - 99˚C
-
0 - 255
-
5 - 22 VDC
-
0 - 99˚C
-
-20 +30˚C
-
0 - 4
-
0 - 24 VDC
-
0 - 8, 53,
-
56
0 - 99 %
-
0 - 105
-
0 - 3
-
3 x 2
-
positions
9