13. Relay Internal / External
With the relay set to "Internal" the E-1600-IP Series Phone will activate its on board relay for door strike / gate control.
The Relay should be set to "External" for higher security installations when using a Viking remote model RC-4A relay
controller to activate the door strike / gate controller (see DOD 582). Factory Setting: Internal

14. Relay Mode

Door Strike Mode. When programmed for Door Strike Mode the relay will momentarily activate for the preprogrammed
relay activation time after detecting the correct relay activation command (one or two digit touch tone) from the called
party.
Outbound Call Mode. When programmed for Outbound Call Mode the relay will activate continuously for the duration
of any outbound call from the Emergency/Entry phone. This mode is useful for activating strobe lights for Emergency
VoIP phones.
Inbound/Outbound Call Mode. When programmed for Inbound/Outbound Call Mode the relay will activate
continuously for the duration of any inbound or outbound call to or from the Emergency/Entry phone. This mode is
useful for turning on IR flood lights, VoIP phones with cameras, etc.
Doorbell Mode. When programmed for Doorbell Mode the relay will momentarily activate the relay for the
preprogrammed relay activation time on any outbound call from the Emergency/Entry phone. This mode is useful for
activating a door chime, etc. When activating door chimes, a 0.5 - 1 second relay activation time is recommended.
LV-1K Control Mode. When programmed for LV-1K Control Mode the relay will activate continuously while the
Emergency/Entry phone is powered and registered to the SIP server. In the event the unit loses power and/or SIP
registration the relay will turn off, activating LV-1K's flashing LED and audible beep signals.
Ring Mode. When programmed for Ring Mode the relay will continuously activate while the ringing extension is called.
This mode is useful for activating a Viking model SL-2 strobe light, etc.
Ring Flash Mode. When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400ms
on/off cadence while the ringing extension is called. This mode is useful for activating a Viking LPL-1 Remote Visual
Indicator, etc.
Factory Setting: Outbound Call