RUGGEDCOM M2100F
Installation Guide
Cabling Category
6
> 6
Follow these recommendations for copper data cabling in high electrical noise environments:
• Data cable lengths should be as short as possible, preferably 3 m (10 ft) in length. Copper data cables should
not be used for inter-building communications.
• Power and data cables should not be run in parallel for long distances, and should be installed in separate
conduits. Power and data cables should intersect at 90° angles when necessary to reduce inductive coupling.
• Shielded/screened cabling can be used when required. Care should be taken to avoid the creation of ground
loops with shielded cabling.
Section 1.5.3

Supported Fiber Optic Cables

The following fiber optic cable types are supported under the stated conditions.
Cable Type
OM1 (62.5/125)
OM2 (50/125)
a
OM3 (50/125)
a
OM4 (50/125)
a
Laser optimized.
Section 1.6

Tamper-Evident Security Seals

In compliance with the security requirements of the Federal Information Processing Standards (FIPS140-2), FIPS-
compliant tamper-evident security seals are applied to potential access points on this device. Security seals provide
evidence of unauthorized tampering or removal of components.
IMPORTANT!
Worn, damaged or missing seals must be replaced immediately.
Replacement seals are available for purchase from Siemens. For more information, contact a Siemens
Sales representative.
Supported Fiber Optic Cables
1000Base-
Required Action
TX Compliant
Yes
No action required.
Yes
Connector and wiring standards to be determined.
Modal Bandwidth
Wavelength (nm)
(MHz·km)
850
1300
850
1300
850
1300
850
1300
100Base-FX
200
500
2000
500
500
2000
1500
500
2000
3500
500
2000
Introduction
Distance (m)
1000Base-SX
10GBase-SR
275
33
550
82
550
300
550
400