Test Equipment Required - Tektronix 485 Instruction Manual

Oscilloscope
Hide thumbs Also See for 485:
Table of Contents

Advertisement

Calibration-485/R485 Service
TABLE 5·1
TEST EQUIPMENT
NOI 'M!urrad fo' Pltrlo,ma.- Chedc.
Examples of Applicable
Description
Minimum Specifications
U....
Test Equipment
Precision Multimeter
Range 0 to 180 V; accuracy
Adjust; CAL 5 V. +59.4 and
Data Precision Digital Mulri-
IDVM)·
within 0.D1%_
SOV supplies; V,rt Comp
meter Model 2400.
Plates;
Grid
Bias;
Auto
Focus; Main Vert Gain; 50
n
Input Impedance.
Check; Vert linearitY.
DC Voltmeter
o
to 4000 V; accuracy within
High Voltage measurement.
Triplett Model 630·NA
0 "
(VDM)l
2%.
precision divider with
th,
DVM.
Time·Mark
Marker output 2 ns to 0.5 s
Adjust;
Geometry;
Horiz
TEKTRONIX
T,po
184
Generator
within 0.1% accuracy; trigger
Gain; Cal 5 V freq; Y Axis; A
Time·Mark Generator.
output 50 05.
timing; B timing; Differential
TEKTRONIX
2901
Time·
timing; Delay Jitter.
Mark Generator.
Medium.Frequency
2 MHz to' 50 MHz; reference
Adjust; A and B trigger; X·Y
TEKTRONIX Type 191 Con-
Constant-Amplitude
frequency.
50 kHz; output
phasing.
stant Amplitude Signal Gen-
Signal Generator
amplitude. 50 mV to 2 V
pop
DIeck; Ext Z Axis blanking;
erator.
into 50 ll; output accuracy,
CMR;
ht
Trigger; Single
within 2%.
Sweep;
X·Y
Bandwidth;
Bandwidth limit.
High·Frequency
Frequency, 100 to 350 MHz;
Vertical bandwidth check.
TEKTRONIX
067-0532-01
Constant·Ampiitude
output amplitude, 0.5 to 5 V;
Calibration Fixture.
Signal Generator
reference frequency. 3 MHz;
accuracy within 1%.
Test Oscilloscope
Bandwidth, DC to 100 MHz;
Adjust: Z Axis Compensation
TEKTRONIX
465
with
deflection factor, 5 mV/div;
"d risetime; Auto Focus;
P6065 Xl0 probe.
accurate within 2%.
CH 1 Trigger Gain.
Amplitude Calibrator
Amplitude, 20 mV to 100 V;
Adjust: 1 Mll amplifier gain.
TEKTRONIX
067-0502·01
and Comparator
accurate to 0.25%.
Check: 1 Mll deflection fac·
Calibration Fixture.
tor. Ext Trig Level range.
50
n
Amplitude
12 mV to 2 V range.
Adjust; CH 1 and CH 2 Gain;
TEKTRONIX
067·0508·00
Calibrator
Invert Gain; Ad"'d
Modo
Calibration Fixture.
Gain; X·Y Gain.
DIeck: 50 II and 1 Mn Gain
match.
Tunnel Diode
Driven
by
th'
T,po
106
Adjust: 50 nand 1 Mn tran-
TEKTRONIX 067-{}681-o1
Pulser
$quare.Wave Generator.
sient response.
Calibration Fixture.
DIeck: Ext Trig Delay Match;
A Ext Trig response.
,
5-2
REV. 8, AUG. 1975

Advertisement

Table of Contents
loading

This manual is also suitable for:

R485