Performing The Weekly Compressor Maintenance - Waterous Eclipse Installation, Operation And Maintenance Manual

Compressed air system
Table of Contents

Advertisement

Safety
Introduction

Performing the Weekly Compressor Maintenance

1
2
Product Overview
Installation
3
Operation
4
5
|
83
90
Maintenance
Troubleshooting
Use the illustrations and instructions to perform the
weekly compressor maintenance. Operating the
compressor in fixed mode with the air discharge
open lubricates and exercises the system.
Note: In humid environments, steam can form and
escape during this procedure.
When performing this procedure:
• Always start the system in auto or unload mode.
• Always circulate enough cool water to regulate
the compressor oil temperature during operation
• Never operate the system with the compressor
oil temperature above 250°F (121°C).
1 Engage the water pump, then make sure that
the pressure is rising.
2 Connect a hose to the auxiliary air outlet.
3 Open the auxiliary air outlet.
4 Engage the compressor, then toggle the
auto-sync switch to the Fixed position.
5 Operate the system for 15 minutes.
6 After completing the procedure, shut down the
"Shutting Down the
system. Refer to:
System" on page 72.