Maintenance; Maintenance Schedule - Waterous Eclipse Installation, Operation And Maintenance Manual

Compressed air system
Table of Contents

Advertisement

Safety
Introduction

Maintenance Schedule

Perform the following procedures at the recommended intervals at a minimum. Environmental conditions affect the maintenance requirements. Inspect the
components frequently and create a maintenance schedule suitable to your application and environment. Replace wear components with equivalent components.
Use your serial number to gain access to the service parts lists associated with your system through the MyWaterous login at www.waterousco.com.
Operation
Operation
Check the oil level.
Inspect the hoses and fittings.
Service operation.
Clean the wye strainer.
Change the oil.
Change the oil filter.
Change the air filter.
Inspect the air clutch and belt drive.
Inspect the mounting hardware.
Change the separator filter.
Product Overview
Before
Before
Daily
Daily
Weekly
Weekly
Operation
Operation
X
X
X
X
X
X
Installation
Operation
12 Months
12 Months
24 Months
24 Months
X
X
X
X
X
X
|
73
90

Maintenance

Troubleshooting
Comment
Comment
Note that the oil level drops temporarily during
system operation.
Operate the system in air only mode once a week for
15 minutes.
Clean the wye strainer after each use. This is
dependent on water quality.
Replace the oil after first 30 hours of operation, then
yearly after that. Use ISO 68 low-foaming or anti-
foam hydraulic oil.
Replace the oil filter when you replace the oil.
Replace the air filter more often in dusty or dirty
environments.
Inspect the equipment during routine maintenance.
Replace the separator filter after a sudden increase
in oil consumption.

Advertisement

Table of Contents
loading

Table of Contents