Operating In Fixed Mode - Waterous Eclipse Installation, Operation And Maintenance Manual

Compressed air system
Table of Contents

Advertisement

Safety
Introduction

Operating in Fixed Mode

4
5
6
1
Product Overview
2
3
Installation
Operation
|
70
90
Maintenance
Troubleshooting
Fixed mode sets the air pressure at a fixed point.
The fixed point for typical applications is 150 psi
(10.3 bar).
Note: The white dots illustrate the main air pressure
route described in the instructions.
1 The compressor builds the air pressure in the
system.
2 Air moves through the system and interacts with
the regulator components.
3 Both solenoids are closed, which allows the air
pressure to operate independently from the
water pressure.
4 Pressure builds until it reaches the set point
when the fixed pressure regulator opens and
allows excess air (pressure) to purge to
atmosphere. To adjust this setting, refer to:
"Calibrating the System—Fixed Mode" on
page 64.
5 As the air (pressure) is purged to atmosphere, it
closes the valve in the air inlet.
6 As the air (pressure) drops, the fixed pressure
regulator closes, the compressor air inlet
opens, the system pressure builds, and the
cycle repeats.

Advertisement

Table of Contents
loading