Troubleshooting
Use the illustrations and instructions to clean the
wye strainer. Purge the pressure from the system
before changing the wye strainer.
High Pressure
• Liquid ejected at high
pressure can cause
serious injury.
• Purge all pressure before
servicing.
1 Open the clean-out valve and allow the system
drain.
2 Remove the clean-out valve and adapting
components.
Note: Replace any worn or deteriorated
washers or O-rings.
3 Remove the strainer from the assembly, then
clean or replace it.
4 Install the strainer into the wye fitting.
Note: Operating the cooler without the strainer
allows debris from the water supply to
damage the system.
5 Install the clean-out valve into the wye fitting.
6 Close the clean-out valve.