The system operates in 3 modes. Each mode is
engaged with the toggle switch on the auto-sync
controller.
When operating the system:
• Always start the system in auto or unload mode.
• Always circulate enough cool water to regulate
the compressor oil temperature during operation.
• Never operate the system with the compressor oil
temperature above 250°F (121°C).
1 To operate in auto mode, toggle the auto-sync
switch to the Auto position. In this mode, the
system synchronizes the air pressure with the
water pressure.
The air pressure rises and falls automatically as
you raise and lower the static water pressure.
Auto mode operates between approximately
50 to 150 psi.
2 To operate in fixed mode, toggle the auto-sync
switch to the Fixed position. In this mode, the
system sets the air pressure to approximately
150 psi.
Fixed mode is used to operate air tools, rescue
bags, etc. Operate the compressor in fixed
mode once a week for 15 minutes per the
maintenance schedule.
3 To operate in unload mode, toggle the switch to
the Unload position. In this mode, the system
operates the compressor in standby.
Approximately 40 psi is produced to circulate
the oil and cool the compressor. In unload
mode, the air pressure and water pressure
work independently.