Connecting the Air Discharges

Use the illustration and instructions to connect the
air discharge solenoids to the relay panel.
Note: The indicator light and wire are supplied by
the installer.
1 Secure the wire to terminal 7 on the relay panel.
2 Install a switch between the relay panel and the
air discharge solenoid.
3 Secure the wire to the cable gland on the
solenoid.
4 Wire the deck gun indicator light into the circuit.
5 Repeat the process to connect the rest of the
air discharge solenoids.