PROGRAMMING
The programming consists of the following settings:
• Unit ID (1..15);
• Door opening time (2 or 6 seconds);
• Conversation time (1 or 2 minutes);
• Addressing order of the buttons.
• Programming mode for Art. 4304X versions.
The settings are carried out through the 8 way dip-switch (reference
PROGRAMMING THE UNIT ID
Switch
Nr.1 Nr.2 Nr.3 Nr.4
ON
OFF OFF OFF OFF
1
2
3
4
5
6
7
8
ON
ON OFF OFF OFF
1
2
3
4
5
6
7
8
ON
OFF ON OFF OFF
1
2
3
4
5
6
7
8
ON
ON
1
2
3
4
5
6
7
8
ON
OFF OFF ON OFF
1
2
3
4
5
6
7
8
ON
ON OFF ON OFF
1
2
3
4
5
6
7
8
ON
OFF ON
1
2
3
4
5
6
7
8
ON
ON
1
2
3
4
5
6
7
8
ON
OFF OFF OFF ON
1
2
3
4
5
6
7
8
ON
ON OFF OFF ON
1
2
3
4
5
6
7
8
ON
OFF ON OFF ON
1
2
3
4
5
6
7
8
ON
ON OFF ON
1
2
3
4
5
6
7
8
ON
OFF OFF ON
1
2
3
4
5
6
7
8
ON
ON OFF ON
1
2
3
4
5
6
7
8
ON
OFF ON
1
2
3
4
5
6
7
8
Art. 4304/4304X -
Installation instructions
ON OFF OFF
ON OFF
ON
ON OFF
ON
ON
ON
ON
ON
on Fig. 2) accessible from the rear side of the module.
H
PROGRAMMING THE DOOR OPENING TIME
ID
Switch
ON
1
1
2
3
4
5
ON
2
1
2
3
4
5
3
PROGRAMMING THE CONVERSATION TIME
Switch
4
ON
1
2
3
4
5
5
ON
1
2
3
4
5
6
PROGRAMMING THE ADDRESSING ORDER OF THE BUTTONS
7
Switch
ON
8
1
2
3
4
5
ON
9
1
2
3
4
5
10
PROGRAMMING MODES (ONLY ART. 4304X VERSIONS)
Switch 8 sets the programming mode: "Standard" (switch in OFF
position) or "Advanced" (switch in ON position).
11
In "Standard" mode settings are made by switches from 1 to 7.
In "Advanced" mode all programming is made via the "VX2X00
12
Programmer" PC software connected to RS485 via an Art. 481 in-
terface. Please note that in this case the programming made by
switches from 1 to 7 wil be ignored.
13
Switch
ON
14
1
2
3
4
5
ON
15
1
2
3
4
5
- 2 -
Nr.5 Setting Up
OFF = 2 seconds
6
7
8
ON = 6 seconds
6
7
8
Nr.6
Setting Up
= 1 minute
OFF
6
7
8
= 2 minutes
ON
6
7
8
Nr.7
Button matrix
OFF = 1 - 40
6
7
8
ON = 41 - 80
6
7
8
Nr.8
Setting Up
OFF "Standard" programming mode
6
7
8
ON "Advanced" programming mode
6
7
8
Setting Up
Internal buttons
= 1, 2
= 41, 42