6.2.2. Output channel with drive ................32 6.2.3. Connection option for zero position sensors ........... 34 Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany Actuator KNX S1R-B4-UP DES • from application 1.0 Status: 27.05.2020 • Subject to technical changes. Errors excepted.
Page 4
Clarification of signs Installation, inspection, commissioning and troubleshooting of the device must only be carried out by a competent electrician. This manual is amended periodically and will be brought into line with new software releases. The change status (software version and date) can be found in the contents footer. If you have a device with a later software version, please check www.elsner-elektronik.de in the menu area "Service"...
Description Description The Actuator KNX S1R-B4-UP DES is an electronic control device for controlling a motor with 3 end switches. A 230 V AC power supply is needed for the motor. Functions: • 1 drive output for a drive with 3 end switches (Venetian blinds with working position) •...
After unpacking the device, check it immediately for possible mechanical damage. If it has been damaged in transport, inform the supplier immediately. Actuator KNX S1R-B4-UP DES • Stand: 27.05.2020 • Technische Änderungen und Irrtümer vorbehalten.
Connection terminal for drive 2.4. Connection The Actuator KNX S1R-B4-UP DES is installed in a flush-mounted box. The connec- tion is made using a KNX connector on the KNX data bus. Actuator KNX S1R-B4-UP DES • Stand: 27.05.2020 • Technische Änderungen und Irrtümer vorbehalten.
230V drive at the output: Each terminal contact may be loaded with a maximum of 10 A. Mains (230 V) 1 2 3 N PE 230 AC V Actuator KNX S1R-B4-UP DES • Stand: 27.05.2020 • Technische Änderungen und Irrtümer vorbehalten.
Disposal After use, the device must be disposed of or recycled in accordance with the legal reg- ulations. Do not dispose of it with the household waste! Actuator KNX S1R-B4-UP DES • Stand: 27.05.2020 • Technische Änderungen und Irrtümer vorbehalten.
RWC- [1.1] DPT_Switch 1 Bit move to shading position Channel A - Automatically Input RWC- [1.1] DPT_Switch 1 Bit move to closed position Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 12
Channel A - Shading Input RWC- [9.4] 2 Bytes brightness measurement 1 DPT_Value_Lux Channel A - Shading Input RWC- [9.4] 2 Bytes brightness measurement 2 DPT_Value_Lux Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 13
RWC- [9.5] 2 Bytes Wind blocking DPT_Value_Wsp measurement Channel A - Blocking 1 - Output R-CT [1.1] DPT_Switch 1 Bit Wind blocking status Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 14
RWC- [9.5] 2 Bytes Wind blocking DPT_Value_Wsp measurement Channel A - Blocking 5 - Output R-CT [1.1] DPT_Switch 1 Bit Wind blocking status Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 15
Output Input 7 - Short Output R-CT [1.8] DPT_UpDown 1 Bit Input 7 - Switch Input / RWCT [1.1] DPT_Switch 1 Bit Output Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 16
2 Bytes DPT_Value_Lux Input 8 - Scene Output R-CT [18.1] 1 Byte DPT_SceneControl Input 8 - Blocking object Input RWC- [1.1] DPT_Switch 1 Bit Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Use an automatic runtime measurement no • yes Runtime UP in sec 1 … 320; 65 Runtime DOWN in sec 1 … 320; 60 Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
(e.g. final position switch or light barrier) may be connected at an input of the actuator (this must be set in the example, if the Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 19
• Stop power supply Behaviour on bus voltage restoration and • no action after programming • Up command • Down1 command • Down2 command Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 20
• yes, as rain blocking Use block 3 • no • yes, with blocking object • yes, as wind blocking • yes, as rain blocking Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 21
(if "Expiration of a waiting period" was chosen) Switch to automatic for an object value 0 • 1 • 0 or 1 (if "Receipt of an object" was chosen) Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 22
The menu item only appears if a wind blocking was configured for "control". The input object "wind blocking" is linked with the output object of a wind sensor. The input can Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 23
The menu item only appears if a rain blocking was configured for "control". The input object "rain blocking" is linked with the output object of a rain sensor. Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
16bit object (measurement value). Use automatic blocking object no • yes Use automatic blocking object Type of temperature input object 1 bit • 16 bit Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 25
16bit object (measurement value or target and actual value). Use inside temperature release no • yes Type of input object 1 bit • 16 bit • 16 bit target/actual temperature Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 26
Type of shading input 1 x 1 bit Drive up delay in min 0 … 255; 12 Departure delay in min 0 … 30; 1 Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 27
Assess position of the sun Position of the sun is defined via • Discreet value of azimuth and elevation • Directions (regarding azimuth and elevation) Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 28
Saving occurs for value = 1 and can for example be realized via a button linked to the teaching object. Numerical specifications already set are overwritten by the teaching object. Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
• as a zero position sensor Use input 2 / 3 / 4 • no • as a bus button • as an actuator switch Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 30
The input can be blocked using a blocking object. Set what is transmitted to the bus when (de)activating blocking. For active blocking there is no cyclical transmission. Use blocking object No • Yes Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 31
The input can be blocked using a blocking object. For active blocking there is no bus communication. Use blocking object No • Yes Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 32
The input can be blocked using a blocking object. For active blocking there is no bus communication. Use blocking object No • Yes Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 33
If monitoring periods or movement range limits are used, no operation via the local button is possible in case of a bus voltage failure. Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
1...50; 10 in 0.1 seconds Repeat the step command every 0.1 s • every 2 sec; every 0.5 sec for a long button press Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 35
The drive moves as soon as the button is actuated and stops as soon as the button is released. Control mode Dead man's switch Behavior during button operation: Push button = Up or Down command Release button = Stop command Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
IN 1 Master command Master Slave Master zero position status Drive 1 Drive 2 Slave zero position status at channel A at channel B Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 37
IN 1 Master command Master Slave Master zero position status Drive 1 Drive 2 Slave zero position status at channel A at channel B Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Page 38
Zero position reached Master command Master Slave Master zero position status Drive 1 Drive 2 Slave zero position status at channel A at channel B Actuator KNX S1R-B4-UP DES • Version: 27.05.2020 • from application 1.0 • Technical changes and errors excepted.
Need help?
Do you have a question about the KNX S1R-B4-UP DES and is the answer not in the manual?
Questions and answers