Parameter and Typical Application
Fig. 9-2: Stop voltage point
H6.10: Relay output selection
Please read through the information on 'Wiring diagram' and 'Terminal' before
the selection of 'Relay output'.
Code
Name
H6.10 Relay output selection
0: Brake chopper fault
●
The output is active when an error occurs, inactive when the error is reset.
1: Brake chopper working
●
The output is active when the brake chopper is running.
2: Brake chopper ready
●
After powering on, if no error occurs and not being in braking state, brake
chopper is ready for running and the output is active.
H6.11: Fan control
This function is used to set the running mode of the fan for the heat sink.
ONLY model 'FEAE07.1-VA2-NNNN' is equipped with fan units.
Code
Name
H6.11 Fan control
0: Automatic
●
46/65
Setting range
0: Brake chopper fault
1: Brake chopper working
2: Brake chopper ready
Setting range
0: Automatic
1: Always on
Brake Chopper
Default
Min.
0
–
Default
Min.
0
–