3.3 Operating principle

Under normal operation conditions there is no compressed air inside the valve body; allowing, thus, the flowing
of the material inside the valve.
In the case of "stimulated" operation, compressed air is present inside the valve body and exerts pressure on
the sleeve, allowing the closing of the valve and, as a consequence, prevents the flowing of the material.
Pi

3.4 Permitted use

The VM Pinch Valve has been designed to intercept the flow of powder or granular material in pneumatic con-
veying systems and, in particular, in pneumatic systems applied to material loading from tanker.

3.5 Improper use not permitted

The standard VM Pinch Valves have NOT been designed to operate in hazardous conditions or with hazardous
materials. If these conditions are met, it is compulsory to inform the manufacturer.
The materials considered being hazardous are the following:
- explosives,
- toxic,
- flammable,
- harmful and / or similar.
The applications considered being hazardous are the following:
- unloading from the silo or cells containing the materials previously indicated
VM