2 Safety

All the information contained in this section refers to hazardous situations.
In addition to the present general safety information the action-related safety
information given in the other sections must be observed.

2.1 General

• This operating manual contains general installation, operating and
maintenance instructions that must be observed to ensure safe operation
of the system and prevent personal injury and damage to property.
• Comply with all the safety instructions given in the individual sections of
this operating manual.
• The operating manual must be read and understood by the responsible
specialist personnel/operators prior to installation and commissioning.
• The contents of this operating manual must be available to the specialist
personnel at the site at all times.
• Information and markings attached directly to the product must always
be complied with and kept in a perfectly legible condition at all times. This
applies to, for example:
– Arrow indicating the direction of rotation
– Markings for connections
– Type designation
• The operator is responsible for ensuring compliance with all local
regulations not taken into account.
2.2 Intended use
• The pump (set) must only be operated in the fields of application and within
the use limits specified in the other applicable documents.
• Only operate pumps/pump sets which are in perfect technical condition.
• Do not operate the pump (set) in partially assembled condition.
• Only use the pump to handle the fluids described in the data sheet or
product literature of the pump model or variant.
• Never operate the pump without the fluid to be handled.
• Observe the minimum flow rates indicated in the data sheet or product
literature (to prevent overheating, bearing damage, etc).
• Observe the minimum flow rate and maximum flow rate indicated in the
data sheet or product literature (to prevent overheating, mechanical seal
damage, cavitation damage, bearing damage, etc).
Do not throttle the flow rate on the suction side of the pump (to prevent
cavitation damage).
• Consult the manufacturer about any use or mode of operation not
described in the data sheet or product literature.