6 Commissioning / Start-up / Shutdown
CAUTION
Table 6. Overview
Characteristic
Head
Flow rate
Immersion depth
Voltage/frequency
Starting current
Maximum temperature
of fluid medium
Particle size
(maximum diameter)
Residual water level
(in manual operation)
Power input
Ingress protection
Power cable
Frequency of starts
(starts/hour)
20 of 32
Installation and operating manual
6 Commissioning / Start-up / Shutdown
6.1 Start-up/shutdown
The pump's automatic control system will cut in when level "A" is reached and
will cut out when level "B" is reached. (
6.2 Operating limits
Unsuitable fluids
Damage to the pump!
Never use the pump to handle corrosive, combustible or explosive fluids.
Never use the pump to handle waste water containing faeces.
Do not use the pump for foodstuff applications..
Delta V3 Pump
6.5 m max.
10 m³/h max.
2 m max.
230 V / 50 Hz
4.1 A
0 to 50 °C
10 mm
15 mm min.
430 W max.
IP68
H05RN8-F 3×0,752
30 max.
Section 5.6, Page 19)
Delta V4 Pump
10 m max.
12 m³/h max.
2 m max.
230 V / 50 Hz
9.5 A
0 to 50 °C
10 mm
15 mm min.
750 W max.
IP68
H05RN8-F 3×0,752
30 max.
Delta V3, V4, V6 Submersible Pump
Delta V6 Pump
12.5 m max.
14 m³/h max.
2 m max.
230 V / 50 Hz
11.5 A
0 to 50 °C
10 mm
15 mm min.
1050 W max.
IP68
H05RN8-F 3×0,752
30 max.