6 Commissioning / Start-up / Shutdown
CAUTION
Table 6. Overview
Characteristic
Head
Flow rate
Immersion depth
Voltage/frequency
Starting current
Maximum temperature
of fluid medium
Particle size
(maximum diameter)
Residual water level
(in manual operation)
Power input
Ingress protection
Power cable
Frequency of starts
(starts/hour)
20 of 32
Installation and operating manual
6 Commissioning / Start-up / Shutdown

6.1 Start-up/shutdown

The pump's automatic control system will cut in when level "A" is reached and
will cut out when level "B" is reached. (
6.2 Operating limits
Unsuitable fluids
Damage to the pump!
 Never use the pump to handle corrosive, combustible or explosive fluids.
 Never use the pump to handle waste water containing faeces.
 Do not use the pump for foodstuff applications..
Delta V3 Pump
6.5 m max.
10 m³/h max.
2 m max.
230 V / 50 Hz
4.1 A
0 to 50 °C
10 mm
15 mm min.
430 W max.
IP68
H05RN8-F 3×0,752
30 max.
 Section 5.6, Page 19)
Delta V4 Pump
10 m max.
12 m³/h max.
2 m max.
230 V / 50 Hz
9.5 A
0 to 50 °C
10 mm
15 mm min.
750 W max.
IP68
H05RN8-F 3×0,752
30 max.
Delta V3, V4, V6 Submersible Pump
Delta V6 Pump
12.5 m max.
14 m³/h max.
2 m max.
230 V / 50 Hz
11.5 A
0 to 50 °C
10 mm
15 mm min.
1050 W max.
IP68
H05RN8-F 3×0,752
30 max.