APMxxxx Series User's Manual
Monitor Tx Channel:
Selects if a Tx frequency will be measured and displayed during each measurement cycle.
Select Tx Port:
Select the Port on which the desired Tx Channel is located.
Select Tx Channel:
Select the Tx Channel that is desired to be monitored.
Note: Only channels that have a frequency configured, and which have been "enabled", will be selectable.
Monitor Rx Channel:
Selects if a Rx frequency will be measured and displayed during each measurement cycle.
Channel:
Select the Rx Channel that is desired to be monitored.
Note: Only channels that have a frequency configured, and which have been "enabled", will be selectable.
Frequency:
Select or Enter the Rx Frequency that is desired to be monitored.
Note:
The frequency may be entered by selecting the field and typing in a value, which may be changed by using the up/down
keys on your keyboard, or by selecting the drop down arrow next to the field and scrolling through and selecting the
desired frequency values.
Select Rx Group:
Select the Group in which the desired Rx Channel is located.
Select Rx Channel:
Select the Rx Channel that is desired to be monitored.
Note: Only channels that have a frequency configured and which have been "enabled", will be selectable.
Displayed Values:
The units of measurement and display for the various values may be changed by clicking on the desired selections.
Start/Stop:
This starts or stops the continuously updating measurements.
The Power and Insertion Loss measurements assume that the Port Coupling losses and the Channel BTx Power have been
previously calibrated (refer elsewhere in this manual).
Note:
When Service Mode is running, the unit will not be monitoring or measuring any other programmed channels.
Clicking the Stop button, navigating to another page within the site, or closing the browser window/tab will restore the
unit's normal operation.
Note:
The Service Mode screen is only visible from the Master and Administrator login levels, it is not visible from
the User login level.