Download Print this page
Equinox Systems Crossfire XP User Manual

Equinox Systems Crossfire XP User Manual

Advertisement

Quick Links

Crossfire XP
User Manual
Order code: EQLED088

Advertisement

loading

Summary of Contents for Equinox Systems Crossfire XP

  • Page 1 Crossfire XP User Manual Order code: EQLED088...
  • Page 2: Safety Advice

    NO USER SERVICEABLE PARTS. pulling the power-cable. • This lighting fixture is for professional use only - it is • Make sure that the available mains supply voltage is not designed for or suitable for household use. The between 100~240V AC, 50/60Hz. product must be installed by a qualified technician in accordance with local territory regulations. The safety of • Make sure that the power cable is never crimped or the installation is the responsibility of the installer. The damaged. Check the equipment and the power cable fixture presents risks of severe injury or death due to fire periodically. hazards, electric shock and falls. • If the equipment is dropped or damaged, disconnect the • Warning! Risk Group 2 LED product according to mains power supply immediately and have a qualified EN 62471. Do not view the light output with optical engineer inspect the equipment before operating again. instruments or any device that may concentrate the beam. • WARRANTY: One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. www.prolight.co.uk Crossfire XP User Manual...
  • Page 3 1 x power cable & 1 x user manual www.prolight.co.uk CROSSFIRE XP POWER INPUT: 100-240V~50/60Hz 01 - Hanging bracket 06 - IEC power output FUSE: T1A 250V POWER OUTPUT 02 - Hanging bracket 07 - Fuse: T1A 250V adjustment knob 08 - 3-Pin XLR DMX input DMX INPUT DMX OUTPUT 03 - LED display 09 - 3-Pin XLR DMX output 04 - Function buttons 10 - Safety eye 05 - IEC power input www.prolight.co.uk Crossfire XP User Manual...
  • Page 4: Master/Slave Mode

    Auto mode: A1 - To access the auto mode, press the “MENU” button on the rear of the unit to show between and A8 - A1 1 A1 9 . Use the “UP” and “DOWN” buttons to adjust the speed between . Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button. Sound active mode: To access the sound active mode, press the “MENU” button on the rear of the unit to show either S2 - (Sound mode 1) or (Sound mode 2). Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button. Master/slave mode: To set the master unit, press the “MENU” button on the rear of the master unit to select your desired program (sound active or auto). A001 To set the other units in slave mode, press the “MENU” button on the rear of the unit to show on the LED display. The unit will now run in sequence with the master unit. To exit out of any of the above options, press the “MENU” button. Please note: When using the fixture in DMX mode and all dimmers are set to 100% the unit will reduce the brightness by approximately 20% to protect the LEDs. www.prolight.co.uk Crossfire XP User Manual...
  • Page 5 A2 1~A2 9 Green - Speed A3 1~A3 9 Blue - Speed A4 1~A4 9 White - Speed A5 1~A5 9 Auto mode 1 - Speed A6 1~A6 9 Auto mode 2 - Speed A7 1~A7 9 Auto mode 3 - Speed A8 1~A8 9 Auto mode with strobe - Strobe speed Sound active mode S1 Sound mode 1 S2 Sound mode 2 Address setting A001~A512 www.prolight.co.uk Crossfire XP User Manual...
  • Page 6: Dmx Setup

    DATA cable (DMX cable) requirements (for DMX operation): This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below. Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers. Please quote: CABL10 – 2m CABL11 – 5m CABL12 – 10m Also remember that DMX cable must be daisy chained and cannot be split. www.prolight.co.uk Crossfire XP User Manual...
  • Page 7: Line Termination

    5-pin XLR (male) 3-pin XLR (female) Pin 1: GND (screen) Pin 1: GND (screen) Pin 2: Signal (-) Pin 2: Signal (-) Pin 3: Signal (+) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk Crossfire XP User Manual...
  • Page 8 Operating instructions & WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk Crossfire XP User Manual...