13. AUXILIARY CONTROL
OUTPUT
NOTE: Use your smartphone camera to access detailed
instructions for Auxiliary output scheduling with
Raymote.
https://www.raypak.com/support/tech-corner/
raymote-automation/
The AVIA heater offers an integrated dry contact relay for
local and remote control of ON/OFF devices like pumps,
water features, valves and lights.
LIGHTS
Figure 142. Device Relay Integration
Auxiliary output is available in terminal P9 "AUX". Use the
supplied harness to control ON/OFF functions or power
switching.
AUXILIARY RELAY
OUTPUT
INTPUT
TEMP
TEMP
P2
P1
Figure 143. Auxiliary Terminal
AUX terminal can be used as direct control or as pilot
relay to a higher rating relay or power contactor. Table S
describes Auxiliary output terminals and ratings.
PUMPS
WATER FEATURES
COM
NO
NC
AUX
POWER BLOWER
P9
Terminal
Wire
Common
Black
Normally Open
Black and Red
Normally Closed Black and White
Table S.
Auxiliary Terminals and Ratings
CAUTION: Do not exceed Auxiliary relay rating.
A
Check power requirements of any electric component
connected to this device, following the applicable
installation norms and requirements.
Use the knockout holes located next to water inlet panel to
route auxiliary harness inside the cabinet to the controller
board. See Figure 144.
Figure 144. Route Communication Harness
It is recommended to use a 1/2" NPT liquid tight cord grip
inserted in the panel knockout hole for better sealing.
AC Rating DC Rating
250V Max,
30V Max,
3A
3A
ROUTE HARNESS
FROM KNOCKOUT
TO CONTROL BOARD
TO AUXILIARY
DEVICE
81