Heater Name
•
Heater name is defined during the Heater connection
and setup. It can be changed anytime from the Heater
settings.
Exit Heater
•
Press X to close Heater view and return to heaters list.
Heater Settings
•
The 3-dot icon opens Heater settings.
•
Use this option to edit the parameters defined during
heater configuration.
POOL-SPA page
•
Displays the page to control the operation mode and
water temperature target.
ACCESSORIES page
•
Displays the page to control Heater Accessories.
Operation Mode selector
•
This 3-button selector can be used to change the
operation mode in the Heater.
•
Use OFF option to stop heating. In this mode the
heater is operational but is maintained in standby until
mode changes to POOL or SPA.
•
Use POOL or SPA mode to set a Water Temperature
target.
•
POOL and SPA mode use an independent temperature
target for each mode.
Heater Status
•
This display shows the current operational status of
heater.
•
No Demand is displayed when the unit is in OFF mode
or when Water Temperature is equal or above the
temperature target.
•
Pre-Purge is displayed when a new heating cycle
starts and the heater is getting prepared for ignition.
66
•
Spark is displayed during the ignition trial.
•
Heating is shown when unit has established a solid
flame and the unit is heating.
•
Post-Purge is displayed when the demand-for-heat is
terminated and unit is getting cooled down.
Water Temperature
•
The water temperature measured by the heater is
displayed in this field.
Setpoint or Target Temperature
•
The water temperature setpoint display and selector
shows the water temperature target.
•
Heater start to hear when Water Temperature is 1
degree Fahrenheit or more, below the setpoint and
operation Mode is POOL or SPA.
Setpoint slider selector
•
The setpoint slider can be used to make quick changes
to the water temperature target.
•
Selection can be fine-tuned with the [+] and [-] buttons
in the setpoint display and selector.
Pool and Spa size
•
The Pool and Spa size displays shows the size
selected in the configuration of the heater when
connected to Raymote.
•
These parameters can be updated from the Heater
Settings page.
Pool and Spa estimated Heat up time
•
These fields displays an estimated heat up time based
in the provided Pool and Spa size, the current water
temperature and the water target temperature.
•
Technical restrictions apply to this estimation.