Rheem Raypak AVIA 264 Installation And Operation Manual page 32

Gas-fired pool and spa heater
Table of Contents

Advertisement

Available languages

Available languages

Wi-Fi Reset
Press the SERVICE key again. "Wi-Fi Reset" appears
on the digital display. To clear stored Wi-Fi signal name
and password, press and hold SERVICE and MODE keys
simultaneously for 3 to 5 seconds until "Wi-Fi Initialized"
appears.
This operation resets the Wi-Fi credentials, leaving the unit
ready to configure connection with the Raymote app. For
details on how to connect your pool heater to Raymote,
follow the instructions on page 51.
Automation Mode
Press the SERVICE key until "Automation Mode" appears
on the digital display. The UP or DOWN keys will select
Enabled or Disabled Automation mode functionality.
When Automation is disabled, Raymote online-scheduled
routines are ignored.
By default, Automation Mode is enabled. For details on
how to configure scheduling and automation with Raymote,
refer to page 63.
Flow Monitoring
Press the SERVICE key until "Flow Monitoring" appears
on the digital display. The UP or DOWN keys will select
"Estimation" or "Flow Sensor" on the Flow Monitoring
function.
By default, Flow Monitoring is set to "Estimated". This
function estimates the flow through the heat exchanger
when unit is in "Heating" status.
Flow Sensor input port (P11) is compatible with an optional
5 VDC hall-effect Flow Sensor. When Flow Sensor option
is enabled, the flow sensor input (P11) translates a pulse
count of 1 Hz to 1 GPM. To calibrate, set a gain using the
Flow Sensor Gain sub-menu.
Sensor Gain
Sensor Gain
1.0
1.0
Flow
Flow
2 GPM
2 GPM
Figure 49. Submenu – Flow Sensor Gain
Protégé Pump Control
Press the SERVICE key until "Pump Control" appears
on the digital display. The UP or DOWN keys will select
"Enabled" or "Disabled". By default, Pump Control option
is Disabled.
Pump Control is compatible with Raypak Protégé VSP and
EVP variable speed pumps.
When "Pump Control" is enabled, the speed configuration
sub-menus are displayed. Use these sub-menus to set up
the 4-speed pump settings.
32
Sensor Gain
Sensor Gain
12.5
12.5
Flow
Flow
25 GPM
25 GPM
Pump Speed1
900 RPM
Pump Speed3
2500 RPM
Figure 50. Submenu – Pump Speeds
Water Chemistry
Press the SERVICE key until "Water Chemistry" appears
on the digital display. The UP or DOWN keys will select
"Enabled" or "Disabled". By default, Water Chemistry is
"Disabled".
These features are compatible with the Raypak Water
Chemistry kit.
Auxiliary Mode
NOTE: This option is available only for units equipped with
2 Auxiliary relays (PCB 1134-83-7506/7606).
Press the SERVICE key until "Auxiliary 1 Mode" or
"Auxiliary 2 Mode" appears on the digital display. The
UP or DOWN keys will select the operation mode of the
Auxiliary relays. The default mode is "Raymote/Manual"
for Auxiliary 1 and 2.
Use UP or Down key to change operation mode selection.
These are the operation modes available for the Auxiliary
outputs:
-Raymote/Manual:
The
commanded from Raymote or from the LCD Service menu.
-Spa mode: The Auxiliary turns ON while the heater is in
Spa mode.
-Pool mode: The Auxiliary turns ON while the heater is in
Pool mode.
-Pool/Spa mode: The Auxiliary turns ON while the heater
is in Pool or Spa mode.
-Blower mode: The Auxiliary turns ON while Blower is On.
-Heat mode: The Auxiliary turns ON while heater is in
Heat status mode.
Auxiliary 1 Mode
Auxiliary 1 Mode
Raymote / Manual
Raymote / Manual
Figure 51. Auxiliary Modes - 2-Aux Boards only
Pump Speed2
1500 RPM
Pump Speed4
2900 RPM
Auxiliary
output
can
Auxiliary 2 Mode
Auxiliary 2 Mode
Switch w/ Blower
Switch w/ Blower
be