Program Menu - Rheem Raypak AVIA 264 Installation And Operation Manual

Gas-fired pool and spa heater
Table of Contents

Advertisement

Available languages

Available languages

Program Menu

To access PROGRAM menu, press and hold SERVICE
and MODE keys simultaneously for 5 to 7 seconds until
"Language" appears on the display.
NOTE: Changes to default program configurations
could affect normal functionality of the heater.
Press the SERVICE key sequentially until the desired
program event is reached. By default, there are 12 different
settings that can be programmed. Additional configurations
for other add-ons are displayed when enabled. Figure 48
lists the default menus.
Language
Language
Lenguaje
Lenguaje
English
English
Español
Español
Set
Defaults
Reset Faults
Temp Display
Fahrenheit
Spa Max Temp
50 F
Pool Max Temp
50 F
WiFi Reset
Automa�on Mode
Enabled
Flow Monitoring
Es�ma�on
Al�tude
Normal
0 to 4500 �
Pump Control
Disabled
Water Chemistry
Disabled
Figure 48. Programmable Settings
Langue
Langue
Français
Français
Defaults Set
Faults Cleared
Temp Display
Celsius
Spa Max Temp
107 F
Pool Max Temp
107 F
WiFi Ini�alized
Automa�on Mode
Disabled
Flow Monitoring
Flow Sensor
Al�tude
High
Above 4500 �
Pump Control
Enabled
Water Chemistry
Enabled
Language Selection
Initial display in PROGRAM Menus is "Language"
selection.
The UP and DOWN keys will select English, Spanish or
French language for all menus and Display messages.
Set Factory Defaults
Press the SERVICE key again. "Set Defaults" option is
displayed. To set factory defaults, press and hold SERVICE
and MODE keys simultaneously for 3 to 5 seconds until
"Defaults Set" appears.
This operation resets the operating program to its factory
default values.
Both the POOL and SPA setpoints will revert to 65°F
(18°C) and both POOL and SPA maximum temperature
settings will be 104°F (40°C). Language is set to English,
temperature display is set to Fahrenheit, Automation Mode
is enabled, Altitude to Normal, Flow monitoring is set to
Estimate, Protége Pump Control and other add-ons are
disabled. The Control Lockout PIN will be cleared and
the control will resume normal operation. See "Control
Lockout" section on page 34.
Reset Faults
Press the SERVICE key again. "Clear Faults" appears
on the digital display. To clear fault history press and
hold SERVICE and MODE keys simultaneously for 3 to 5
seconds until "Faults Cleared" appears.
Temperature Display
Press the SERVICE key again. "Temp Display" appears
on the digital display. The UP or DOWN keys will select
Fahrenheit or Celsius on the temperature display. Choose
the desired temperature scale.
Spa Setpoint Maximum Adjustment
Press the SERVICE key until "Spa Max. Temp" appears
on the digital display. Using the UP and DOWN keys will
change the Maximum Temperature Setting to your desired
value. The control can be set for a maximum of 107°F
(42°C).
Pool Setpoint Maximum Adjustment
Press the SERVICE key until "Pool Max. Temp" appears
on the digital display. Using the UP and DOWN keys will
change the Maximum Temperature Setting to your desired
value. The control can be set for a maximum of 107°F
(42°C).
WARNING: Ensure to properly setup pool and spa max
setpoint limits. Setpoint should never exceed above
107° F (42°C).
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Raypak avia 404