Water/Flue Connection Reversal; Electrical Wiring; Electrical Power Draw - Rheem Raypak AVIA 264 Installation And Operation Manual

Gas-fired pool and spa heater
Table of Contents

Advertisement

Available languages

Available languages

Water/Flue Connection Reversal

The heater is designed so that the control panel along with
the top can rotate in 90-degree increments to face the user.
90°
Flue Connection
or Outdoor Cover
Figure 26. Connection Reversal
To rotate the top, remove the (2) knurled screws holding
the jacket top to the heater as shown below. Rotate the top
to the desired position and reinstall the knurled screws to
retain the jacket top. See Figure 34 on page 27.
NOTE: To prevent wire harness damage, ensure
harnesses are out of the way when handling the top
cover.
SCREW HOLE
CONTROLS
HARNESS
Figure 27. Rotate Jacket Top
24
90°
Water
Connections
Display
ROTATE
THE TOP
SCREW HOLE

5. ELECTRICAL WIRING

NOTE: If it is necessary to replace any of the original
wiring, use 150°C wire or its equivalent.
A
WARNING: The heaters are factory-wired for 240
VAC, 1Ph, 60Hz power supply. DO NOT attempt to
operate at 208 VAC or below.
NOTE: Holes not utilized on jacket and electric junction
box, can be used for remote mode selector, Protégé VS
pump wiring, or auxiliary control interface.

Electrical Power Draw

A
CAUTION: A bonding lug is located below the
junction box. Failure to ground the heater electrically
could affect the heater's electronics. A Bonding Wire
must be installed as per NEC requirements to safeguard
persons and property.
NOTE: See "Time Clock/Fireman's Switch" on page
38 for further instructions if using a time clock/
fireman's switch.
The Electronic Ignition Device automatically lights the
burner upon a call-for-heat. The heater is supplied with a
dual-voltage transformer for 120 VAC or 240 VAC input
power hookup. Factory default configuration is 240 VAC.
When using 120VAC, wire the transformer per Figure 29
and change the blower jumper per Figure 30.
When operating on 120 VAC power, units draw
approximately 1.6 amps. When operating on 240 VAC
power, units draw approximately 1.2 amps.
POWER
SUPPLY
BONDING
LUG
Figure 28. Heater Wiring Locations