Control Lockout; Status And Diagnostics - Rheem Raypak AVIA 264 Installation And Operation Manual

Gas-fired pool and spa heater
Table of Contents

Advertisement

Available languages

Available languages

Control Lockout

The heater is equipped with a Control Lockout feature
to prevent unauthorized tampering or adjustment of the
control settings. To lock out the controls, press the MODE
and DOWN keys simultaneously for 5-seconds. Choose
a three-digit PIN, using the UP and DOWN keys to select
the digits and the MODE key to lock in selections. Confirm
your selection and record your PIN.
Control Lockout
Enter PIN
Confirm Lockout
Yes
Figure 53. Control Lockout
To unlock the controls, press MODE, UP or DOWN key
to bring up the ENTER PIN menu. Enter the PIN that
was used to lock the control. Note that power cycling will
not clear the lockout. Successfully unlocking the control
will display "LOCKBOX CLEARED". Failure to enter the
correct PIN will display "INVALID PIN".
In the event that the user-selected PIN is lost or does not
clear the Control Lockout, use the Program Menu to SET
FACTORY DEFAULTS. This will clear the PIN and allow
normal operation and selection of a new PIN if desired.
See the "Program Menu" section on page 31 for details.
NOTE: By setting FACTORY DEFAULTS, both the POOL
and SPA setpoints will revert back to 65°F (18°C) and the
POOL and SPA maximum temperature settings will be
104°F (40°C). These setpoints will need to be readjusted
to desired settings. Other default configurations are also
applied.
34

Status and Diagnostics

The LCD displays a variety of status and diagnostic
messages, depending on the operating conditions.
The following status messages are displayed in Pool,
Spa, and Remote modes when there are no active fault
conditions.
Display
No Demand
000
Verifying
Pre-Purge
Heating
Post-Purge
Water temperature is equal or above
setpoint.
2-min wait for water pressure/flow
Water
Call-for-heat established.
Spark
Spark operating.
Flame present. Unit is heating.
Heating is terminated. Unit cool down.
Table O.
Heater Status Messages
Condition

Advertisement

Table of Contents
loading

This manual is also suitable for:

Raypak avia 404

Table of Contents