MAGSTIM 3190-00 Operating Manual

MAGSTIM 3190-00 Operating Manual

2nd generation coils
Hide thumbs Also See for 3190-00:

Advertisement

Magstim 2nd Generation Coils
Operating Manual
MOP04-EN
Revision 03
FEB 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3190-00 and is the answer not in the manual?

Questions and answers

Summary of Contents for MAGSTIM 3190-00

  • Page 1 Magstim 2nd Generation Coils Operating Manual MOP04-EN Revision 03 FEB 2015...
  • Page 2: Table Of Contents

    Product Enquiries ....................20 Servicing Enquiries ....................20 Sales Enquiries ..................... 20 Appendix A - Error Codes ....................21 Appendix B - TMS MEDICAL SCREENING QUESTIONNAIRE ..........22 Appendix C - EMC IMMUNITY AND EMMISIONS ..............26 © The Magstim Company Limited MOP04-EN-03...
  • Page 3: Guarantee

    Equipment manufactured by The Magstim Company Limited is fully guaranteed, covering both materials and workmanship, for a period of one year from the date of shipment. The Magstim Company Limited reserves the right to perform guarantee services in its factory, at an authorised repair station, or at the customer’s installation.
  • Page 4: Introduction

    Magstim recommends that a standard questionnaire is completed to screen a patient’s suitability prior to using any Magstim product on that patient and concurs with the recommendations given in the paper titled “Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research”...
  • Page 5: Frequently Used Functions

     Magstim BiStim² stimulator - MOP02 Frequently Used Functions  Frequently used functions as defined during Magstim’s usability process are identified with (*). Frequently used functions are functions of the 2 Generation Coils that frequently involve user interaction. © The Magstim Company Limited...
  • Page 6: Warnings And Precautions

    Damage: If there are any signs of damage to the Coils, or if any parts are damp or wet, the coil must not be used*. If damaged, the coil should be returned to the Magstim Company Limited for servicing and repair (see Section 7.2 for contact details).
  • Page 7 The use of ear protection is recommended for the operator and adult patients. Ear protection is mandatory for children. Seizures: cortical magnetic stimulation runs the risk of inducing seizures. Magstim concurs with the advice given in the paper titled “Safety, ethical considerations and application guidelines for the use of TMS in clinical practice and research”...
  • Page 8: Product Descriptions

    Coil connector Coil head Coil handle Figure 3.1: Example Coil illustration (3190-00 – D70mm Remote Control Coil) Double 70mm Remote Control Coil This coil has a figure-of-eight winding in the coil head. Current flow is in opposing directions in each half of the coil, which is indicated by the current direction label (see Figure 3.2).
  • Page 9: Single 90Mm Remote Control Coil And Single 90Mm Standard Coil

    5. Multi-function display 4. Down Button 3. Ready Indicator 6. Up button 2. Stop Button 1. Multi-function 7. Temperature button indicator Figure 3.6: User interface on a Remote Control Coil © The Magstim Company Limited MOP04-EN-03...
  • Page 10 3.4.1.4 Down Button* (4) When used with the Magstim 200² or Bistim² engaging the down button will reduce the selected parameter by one unit. If the button is held, the parameter will continue to decrease until the button is released or the minimum value is reached.
  • Page 11 The coil temperature indicator will be illuminated when the coil surface temperature has reached the maximum limit. If this symbol is illuminated, the coil should be removed from the subject and allowed to cool. © The Magstim Company Limited MOP04-EN-03...
  • Page 12: Operating Instructions

    The Magstim Company Limited for servicing and repair. (See section 5.4 for servicing details). If cleaning is required, please follow the instructions provided in Section 5.3.
  • Page 13: Operation

    Operation 4.3.1 Use of Remote Control Coils with Magstim 200² When the coil is connected to the stimulator and ready to use, remove the coil from the coil holder of the right hand side of the stimulator*. The coil will show the output power of the system on the multi-function display*.
  • Page 14 4.3.2 Use of Remote Control Coil with Magstim Bistim² When the coil is connected to the stimulator and ready to use, remove the coil from the coil holder of the right hand side of the master unit*. The coil multi-function display* will show one of the values listed below.
  • Page 15 Note: Ensure that the system is disarmed prior to disconnecting the stimulating coil from the stimulator 4.3.4 Use of the Standard Coil with Magstim 200², BiStim² and Rapid² When the coil is connected to the stimulator and ready to use, select the desired stimulator output power/ protocol using the stimulator UI.
  • Page 16: Interlocks

    Generation Coils will display the appropriate error code on its display. (See Appendix A for a list of the error codes for faults relating directly to the operation of the 2 Generation Coils). Note: Details on Stimulator error codes can be found in the appropriate Stimulator operating manual. © The Magstim Company Limited MOP04-EN-03...
  • Page 17: Maintenance

    Continued use in this condition will eventually cause the contacts to deteriorate and loose electrical connection, which will cause damage to the system. Repair is a specialised procedure and can only be undertaken by The Magstim Company Limited or an authorised service centre. If any pins show damage, however slight, contact The Magstim Company Limited service department for further advice or to arrange a return (see Section 7.2 for...
  • Page 18: Disposal

    Generation Coils reaches the end of its serviceable life, it should not be disposed of in general waste. The Magstim Company Limited should be contacted (see Section 7.2 for contact details) for advice on its disposal in compliance with the appropriate environmental regulations.
  • Page 19: Specifications

    Generation Coils are not protected against flammable anaesthetic mixtures. They are not suitable for use in the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide. The mode of operation of the 2 Generation Coils is classified as continuous. © The Magstim Company Limited MOP04-EN-03...
  • Page 20: Technical Specifications

    100% 100% Power Power Power When used with a Magstim 200², at an ambient temperature of 20°C. Table 6.1: Coil specifications 6.2.1 Electric Field Plot Figure 6.1: Approximate electric field profile for 90mm Remote Coil and 90mm Standard Coil measured using a Magstim Rapid²...
  • Page 21 Magstim 2nd Generation Coils Operating Manual Figure 6.2: Approximate electric field profile for D70mm Remote Coil measured using a Magstim Rapid² 6.2.2 Magnetic Field Plot Figure 6.3: Approximate Magnetic Field Profile for 90mm Remote Coil and 90mm Standard Coil measured using a Magstim Rapid²...
  • Page 22: Environmental Conditions

    Magstim 2nd Generation Coils Operating Manual Figure 6.4: Approximate Magnetic Field Profile for D70mm Remote Coil measured using a Magstim Rapid² Environmental Conditions Operating temperature: 5°C to 40°C Transport and storage temperature: -19°C to 60°C Operating, transport and storage relative humidity:...
  • Page 23: Contact Details

    +44 (0)1994 240798 Fax: +44 (0)1994 240061 E-mail: magstim.info@magstim.com Website: www.magstim.com Servicing Enquiries Telephone: +44 (0)1994 242900 Fax: +44 (0)1994 240061 E-mail: service@magstim.com Sales Enquiries Telephone: +44 (0)1994 241111 Fax: +44 (0)1994 242917 E-mail: sales@magstim.com © The Magstim Company Limited MOP04-EN-03...
  • Page 24: Appendix A - Error Codes

    Invalid Coil Power Identification (Coil adapter only). Hardware Stop activated. Watchdog Timeout. Temperature Interlock 3 activation. Coil stop line fault. For diagnosis, contact The Magstim Company Limited service department (see Section 7.2 for contact details). © The Magstim Company Limited MOP04-EN-03...
  • Page 25: Appendix B - Tms Medical Screening Questionnaire

    APPENDIX B - TMS MEDICAL SCREENING QUESTIONNAIRE The Magstim Company Limited takes your health and safety very seriously and as such, it is necessary to point out that there is a remote possibility of adverse effects occurring as a result of receiving Transcranial Magnetic Stimulation (TMS). Such effects can include a risk of seizure, headache, pain and nausea in particular susceptible individuals.
  • Page 26 Magstim 2nd Generation Coils Operating Manual The Magstim Company accepts no responsibility for adverse reactions resulting from (TMS) where false or inaccurate medical information is supplied. Magstim have strict confidentiality policies and we confirm that your information will be kept securely and will not be passed on to any other third party.
  • Page 27 If the respondent answers yes or don’t know, do not administer TMS.  Have you consumed alcohol within the last 12 hours? Please use the following guidelines for alcohol consumption. If the daily or weekly amounts have been exceeded do not administer TMS. © The Magstim Company Limited MOP04-EN-03...
  • Page 28 Have you undergone TMS in the past and had any adverse affects? If the respondent answers yes or don’t know, do not administer TMS.  Have you had a reasonable night’s sleep? If the respondent answers no or don’t know, do not administer TMS. © The Magstim Company Limited MOP04-EN-03...
  • Page 29: Appendix C - Emc Immunity And Emmisions

    The Magstim Rapid System is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Magstim Rapid System can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF...
  • Page 30 EN61000-4-6 amplitude 3530-00 between 30MHz compliant with EN60601-1-2. modulation and 80MHz may produce system errors setting system into safe mode. NOTE is the a.c. mains voltage prior to application of the test level © The Magstim Company Limited MOP04-EN-03...
  • Page 31 If the measured filed strength in the location in which the Magstim Rapid System is used exceeds the applicable RF compliance level above, the Magstim Rapid System should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Magstim Rapid System.
  • Page 32 The Magstim 200 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Magstim 200 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF...
  • Page 33 NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. © The Magstim Company Limited MOP04-EN-03...
  • Page 34 Meets requirement Equipment should only be used in Immunity 2Hz 80% the vicinity of other equipment EN61000-4-6 amplitude compliant with EN60601-1-2. modulation NOTE is the a.c. mains voltage prior to application of the test level © The Magstim Company Limited MOP04-EN-03...
  • Page 35 If the measured filed strength in the location in which the Magstim 200 is used exceeds the applicable RF compliance level above, the Magstim 200 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such...