Harvia KIP-30-B1 Owner's/Operator's Manual page 5

Hide thumbs Also See for KIP-30-B1:
Table of Contents

Advertisement

Available languages

Available languages

Internal wiring only
240 V 1 PHASE HEATER
KIP-30-B1 / KIP-45-B1 / KIP-60-B1 / KIP-80-B1
1
1
2 3
LINE 1
LINE 2
Figure 5.
SAUNA HEATER (240 V) WITH BUILT IN CONTROLS
Model
kW
Amps
KIP-30-B1 3.0
12.5
KIP-45-B1 4.5
18.8
KIP-60-B1 6.0
25.0
KIP-80-B1 8.0
33.3
THERMOSTAT BULB LOCATION (HEATERS WITH BUILT IN CONTROLS)
12''/ 305mm
3
2
TIMER
LIMIT CONTROL
GROUND
GND
Voltage
Phase
Wire size
240
1
#12/2
240
1
#10/2
240
1
#10/2
#8/2
240
1
7 to 12''/
178 to 305mm
Internal wiring only
208 V 3 PHASE HEATER
KIP-30-B3 / KIP-45-B3 / KIP-60-B3 / KIP-80-B3
1
2
1
2 3
LINE 1
LINE 3
LINE 2
SAUNA HEATER (208 V) WITH BUILT IN CONTROLS
Model
kW
Amps
KIP-30-B3 3.0
8.3
KIP-45-B3 4.5
12.5
KIP-60-B3 6.0
16.7
KIP-80-B3 8.0
22.2
12''/ 305mm
3
TIMER
LIMIT CONTROL
GROUND
GND
Voltage
Phase Wire size
208
3
#14/3
208
3
#14/3
208
3
#12/3
#10/3
208
3
Figure 5a.
5