Hazardous area considerations

The transmitter must be installed in hazardous area only if it is
properly certified. The certification plate is permanently fixed
on the neck of the transmitter top housing. The 266 Pressure
Transmitter Line can have the following certifications:
• ATEX Intrinsic Safety Ex ia (code E1)
• ATEX Explosion Proof Ex db_tb (code E2)
• ATEX Intrinsic Safety Ex ic_tc (code E3)
• Combined ATEX Ex ia, Ex db_tc and Ex ic_tc (code EW)
• IECEx Intrinsic Safety Ex ia (code E8)
• IECEx Explosion Proof Ex db_tb (code E9)
• IECEx Intrinsic Safety Ex ic_tc (code ER)
• Combined IEC Approval Ex ia and Ex db_tb (code EH)
• Combined IEC Approval Ex ia, Ex db_tb and Ex ic_tc (code EI)
• FM Approvals (Canada) approval (XP, DIP, IS, NI) (code E4)
• FM Approvals (US) approval (XP, DIP, IS, NI) (code E6)
• FM Approvals (US and Canada) Intrinsically safe (code EA)
• FM Approvals (USA and Canada) Nonincendive (code EC)
• Combined FM (code EB) approvals (US and Canada)
• Combined ATEX, IECEx and FM Approvals (US and Canada)
(code EN)
Type 4X, IP66, IP67 for all above markings.
See relevant paragraph for complete markings details.

Pressure Equipment Directive (PED)

(2014/68/EU)

Devices with PS >200
Devices with a permissible pressure PS >200 bar have been
subject to a conformity validation. The data label includes the
specifications relevant to Pressure Equipment Directive (PED)
(2014/68/EU).
jl
1 1 1 1
ABB S.p.A.
1
1
,
9
9
Q ______
M
a
e
d
i
n
l
t a
Y __ N
l
_
_
_
_
_
_
_
_
_
_
_
PRODUCT CODE
ACC-H
SPEC.REQUEST
SENSOR DIAPH.-FILL
FLANGE/CONN. -GASKET /S
� H DIAPH.-FILL
L DIAPH.-FILL
en
POWER SUPPLY
TS
MWP/OVP
LRL/URL
SPAN LIMITS
Figure 5: 266DDS nameplate with PED data
Devices with PS ≤ 200
Devices with a permissible pressure PS ≤200 bar correspond
to article 3 paragraph (3). They have not been subject to a
conformity validation. These instruments were designed and
manufactured according to SEP Sound Engineering Practices.