1.5 Three additional pulse inputs (optional; only in conjunction with M-Bus or radio)
With this option, additional instruments with pulse outputs can be read out via optical interface, M-Bus or radio.
General information about pulse inputs:
It is important to note that the acknowledged state of the art technology rules and the relevant legal restraints (international
and local; see "Relevant Norms / Standards / Literature Pulse Inputs") are to be observed.
The installation has to be performed by authorized, skilled persons.
If the regulations and the information in the installation and operating instruction manuals are not strictly followed, or if the
installation is shown to be faulty, any resulting expenses will be charged to the company responsible for the installation.
1.5.1 Relevant norms / standards / literature pulse inputs
IEC 60364-4-41 (2005-12)
IEC 60364-4-44 (2007-08)
IEC 60364-5-51 (2005-04)
IEC 60364-5-54 (2011-03)
EN 50310 (2011)
EN 1434-2 (2016)
1.5.2 Technical data pulse inputs
Pulse input class
Connecting cable length
Voltage supply
Source current
High level input threshold
Low level input threshold
Pull-up resistor
Pulse length
Pulse frequency
1.5.3 Possible combinations of the different input (class IB) and output (class OA) devices
Class OA
Class OB
Class OC
Class OD
Class OE
1.5.4 Setting up the three additional pulse inputs
The optional pulse inputs 1 + 2 + 3 for external meters can be set up using a suitable configuration software. You can configure
serial number, manufacturer, version (0 ... 255), medium code, input pulse value, unit and starting value of the external
meters.
52 / 107
Low-voltage electrical installations - Part 4-41: Protection for safety - Protection against
electric shock
Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against
voltage disturbances and electromagnetic disturbances
Electrical installations of buildings - Part 5-51: Selection and erection of electrical
equipment - Common rules
Low-voltage electrical installations - Part 5-54: Selection and erection of electrical
equipment - Earthing arrangements and protective conductors
Application of equipotential bonding and earthing in buildings with information
technology equipment
Heat Meters - Part 2: Constructional requirements
IB according to EN 1434-2:2016
1 m
+ 3 V DC
= 1,5 µA
U ≥ 2 V
U ≤ 0,5 V
2 MΩ
≥ 100 ms
≤ 5 Hz
Class IA
Class IB
yes
yes
yes
no
no
yes
no
no
no
no
1080619050 / MH 4310 INT5
Class IC
Class ID
no
yes
no
yes
yes
no
yes
no
no
no
2022_09_22 V 0001
Class IE
no
yes
no
no
yes