FLIR Ariel Gen III CB-330 Series User And Installation Manual page 80

Table of Contents

Advertisement

Configuration and Operation
·
Normal – When this is selected, a new field (Post Duration) is displayed. The Post Duration time
determines the length of time that the alarm is triggered. It can be set to Infinite (the alarm is active
until deactivated) or set to 5, 10, 15, or 30 seconds.
9.3.1.6.3 FTP
The FTP screen is used for configuring the settings of an FTP server located remotely on the network. The
server is used for saving snapshots of events that are configured from the
transmitted from the camera via FTP to the remote FTP server.
To configure FTP server settings
1. In the Server Address text box, enter the FTP server IP address.
2. In the Port text box, enter the email server port number.
3. In the User Name text box, enter the FTP server user name.
4. In the Password text box, enter the FTP server manager's password.
5. From the Mode drop-down list, select Active or Passive (default setting). In passive mode, FTP the
client initiates both connections to the server, solving the problem of firewalls filtering the incoming
data port connection to the client from the server. In order to support passive mode FTP on the
server-side firewall, the following communication channels must be opened:
·
FTP server's port 21 from anywhere (client initiates connection)
·
FTP server's port 21 to ports > 1023 (server responds to client's control port)
·
FTP server's ports > 1023 from anywhere (client initiates data connection to
random port specified by server)
·
FTP server's ports > 1023 to remote ports > 1023 (server sends ACKs and
data to client's data port)
6. Click Save.
74
Alarm Out Screen - Normal
Events Handler > FTP Screen
CB-3304/CB-3308 User and Installation Guide
Events Source
section and
September 11, 2017

Advertisement

Table of Contents
loading

Table of Contents