Full Gauge Controls MT-532 Super Quick Start Manual

Full Gauge Controls MT-532 Super Quick Start Manual

Temperature and humidity digital controller with serial communication

Advertisement

Quick Links

1. DESCRIPTION
MT-532 %uper is an instrument that indicates and controls the environment temperature and
humidity, indicated for low and average relative air humidity (from 0 to 100%, without condensation) and
temperature of -10 to 70ºC. Its sensors of temperature and humidity are joined in an only bulb, that
reduces the space in wiring of the installation.
The instrument has the THERM output with a solid state relay (SSR) and serial communication for
®
connection with the
SITRAD
via Internet.
2. APPLICATION
• Humidificators/dehumidificators
• Grains drying
• Laboratories
• Surgical rooms
• Climatized cellars
• Information technology centers
• Incubators
Note 1: For climatization and storage of fruits and flowers, use the model AHC-80 plus
3. TECHNICAL SPECIFICATIONS
- Power Supply: 115 or 230 Vac ±10%(50/60 Hz)
- Control Temperature: -10 to 70.0 ºC ±1.5°C (with resolution of 0.1°C)
14 to 158 ºF ±3°F (with resolution of 1°F)
- Control Humidity: 10 to 85%RH ±5%RH (with resolution of 0.1%RH)
- Load current:
THERM - 2A/250Vac
HUMID - 5(3)A/230Vac 1/8HP
AUX - 5(3)A/250Vac 1/8HP
- Dimensions: 71 x 28 x 71 mm
- Operation temperature: 0 to 50°C
32 to 122°F
- Operation humidity: 10 to 85% RH (without condensation)
Note 2: For environments with condensation uses the model AHC-80 plus.
4.4 - Parameters description
Fun
Access code: 123 (one hundred and twenty-three)
Thermostat operation mode (THERM output)
Minimum setpoint allowed to the user (thermostat)
Maximum setpoint allowed to the user (thermostat)
Control differential (hysteresis) of the thermostat
Minimum delay to turn the thermostat output on
Humidistat operation mode (HUMID output)
Minimum setpoint allowed to the user (humidistat)
Maximum setpoint allowed to the user (humidistat)
Control differential (hysteresis) of the humidistat
Minimum delay to turn the humidistat output on
Humidity output (time on)
Humidity output (time off)
Auxiliary output operation mode (AUX)
Minimum setpoint allowed to the user (AUX output)
Maximum setpoint allowed to the user ( AUX output )
Control differential (hysteresis) of the AUX output
Minimum delay to turn the AUX output on
Time base of AUX output timer
AUX output (time on)
AUX output (time off)
Low room temperature alarm
High room temperature alarm
Low room humidity alarm
High room humidity alarm
Minimum delay to turn the AUX output on (alarm mode)
Buzzer operation mode
Acting point of Buzzer by low temperature
Acting point of Buzzer by high temperature
Acting point of Buzzer by low humidity
Acting point of Buzzer by high humidity
Maximum time of the activated THERM output to activate the alarm
Maximum time of the activated HUMID output to activate the alarm
Maximum time of the activated AUX output to activate the alarm
Buzzer time on
Buzzer time off
Inhibition time of Buzzer during electrical supply
Output status in case of alarm
Display mode
Temperature display offset
Humidity display offset
Network equipment address RS-485
MT-532 %uper
TEMPERATURE AND HUMIDITY
DIGITAL CONTROLLER WITH
SERIAL COMMUNICATION
Ver.02
Description
4. CONFIGURATIONS
4.1 - Temperature and humidity adjust (SETPOINTS):
- Press
for 2 seconds until
SET
temperature for THERM output will appear.
- Use the keys
and
to change the value and then press
- Now
and adjusted humidity for HUMID output will appear.
- Use the keys
and
to change the value and then press
-Then, if the AUX output is set to control (F14 = 0, 1, 2 or 3)it may appear
- Use the keys
and
to change the value for the AUX output and then press
4.2 - Parameters configuration
- Access the function F01 pressing simultaneously the keys
, releasing after that. Soon it will appear
- Use the keys
and
to enter acess code (123) and, when ready press
- Use the keys
and
to access the desired function.
- After selecting the function, press
- Use the keys
and
to change the value, and when ready, press
value and return to the menu of functions.
- To leave the menu of functions and return to normal operation, press
CELSIUS
Min.
Max.
Unit
Standard
-99
999
-
-
0 - refrig.
1 - heat
0 - refrig.
-
0
-10
70.0
°C
-10
-10
70.0
°C
70.0
0.10
20.0
°C
01.5
000
999
sec.
000
0 - dehum.
1 - humid.
-
1 - humid.
0 - dehum.
00.0
100
%RH
00.0
000
100
%RH
100
0.10
20.0
%RH
05.0
000
999
sec.
000
000
999
sec.
005
000
999
sec.
005
000
010
-
005
00.0
100
-
00.0
000
100
100
-
05.0
0.10
20.0
-
000
999
000
sec.
000
000
3
-
000
999
005
sec.
005
000
999
sec.
-10
70.0
-10
°C
-10
70.0
70.0
°C
00.0
100
00.0
%RH
000
100
100
%RH
000
999
000
min.
0
1
1
-
-10.0
70.0
-10
°C
-10.0
70.0
70.0
°C
00.0
100
00.0
%RH
000
100
100
%RH
000
999
min.
000
999
min.
000
999
min.
sec.
000
999
001
000
999
sec.
001
min.
000
999
000
0
1
-
0
0
2
-
0
-5.0
5.0
°C
00.0
-20.0
20.0
%RH
00.0
001
247
-
001
appears, then release it. The indication
to record it.
SET
again.
SET
and
for 2 seconds until appearing
, and then press
(short touch).
SET
SET
(short touch) to visualize the value configured for that function.
SET
SET
to memorize the configured
SET
SET
until appear
SET
SET
FAHRENHEIT
Max.
Standard
Min.
Unit
-99
999
-
-
1 - heat
-
0 - refrig.
014
158
°F
14
014
158
°F
158
001
36
°F
003
000
999
sec.
000
1 - humid.
-
1 - humid.
000
100
%RH
000
000
100
%RH
100
0.10
20.0
%RH
005
000
999
sec.
000
000
999
sec.
005
000
999
sec.
005
000
010
-
005
00.0
100
-
00.0
000
100
100
-
05.0
0.10
20.0
-
000
999
000
sec.
000
000
3
-
000
999
005
sec.
000
999
005
sec.
14
158
014
°F
14
158
158
°F
00.0
100
00.0
%RH
000
100
100
%RH
000
999
000
min.
0
1
1
-
14
158
014
°F
14
158
158
°F
00.0
100
00.0
%RH
000
100
100
%RH
000
999
min.
000
999
min.
00 0
999
min.
001
000
999
sec.
000
999
001
sec.
000
000
999
min.
0
1
0
-
0
2
0
-
00.0
-9
9
°F
-20.0
20.0
00.0
%RH
001
247
001
-
and the adjusted
or
.
to record it.
SET
to confirm.
SET
SET
.

Advertisement

loading

Summary of Contents for Full Gauge Controls MT-532 Super

  • Page 1 MT-532 %uper TEMPERATURE AND HUMIDITY DIGITAL CONTROLLER WITH SERIAL COMMUNICATION Ver.02 1. DESCRIPTION 4. CONFIGURATIONS MT-532 %uper is an instrument that indicates and controls the environment temperature and 4.1 - Temperature and humidity adjust (SETPOINTS): humidity, indicated for low and average relative air humidity (from 0 to 100%, without condensation) and - Press for 2 seconds until appears, then release it.
  • Page 2 Example: Humidification F23 - High room temperature alarm Control = 80% RH *Time of HUMID output on = 20 sec Temperature for activation of the high temperature alarm. Hysteresis = 5% RH *Time of HUMID output off = 10 sec When humidity falls to 75% RH (80 - 5), the humidistat output starts to cycle: 20 sec.
  • Page 3 IMPORTANT 6. SIGNALLING According to the chapters from the IEC60364 standard: Led THERM on - T hermostat output on 1: Install protectors against over voltage on power supply. Led HUMID on - H umidistat output on 2: Sensor cables and computer signals can be together, however not at the same place where power Led AUX on - Auxiliar output on Led BUZZ on -...