Services Menu

14.4 Screen

Screen
Screen calibration
Screen brightness

14.5 Buzzer

Buzzer
Adjust the sounds available on the instrument.
When "screen tap" is enabled, a click sound is heard each time the screen is touched.
The instrument alarm sound can be enabled or disabled to suit the application. The sound type can also
be adjusted. Press the Test button to test the adjustment made. Press again to stop.

14.6 Boards info

Boards info
Main board info
Measurement board info For reference, this display gives information on the sensor measurement
Sensor parameters

14.7 Batteries

Batteries
On all instruments this display gives the real time clock battery charge level and voltage.
Note: A warning message (and icon) is displayed if the battery level becomes too low and needs to be
replaced.

14.8 Software download

Software download
For Hach technician use only. Used when reloading the software for new versions.
This ends the application. User must stop and restart the instrument to restart the program.

14.9 End application

End application
This ends the application. User must stop and restart the instrument to restart the program.
100
This screen allows you to adjust the click position corresponding to the
displayed buttons. Use it if ever the sensitive areas are no longer properly
aligned with the buttons on display.
Place the stylus right on the cross when asked and proceed. User will be
asked to press on the screen to accept the new setting. If not, the new
setting is not recorded and no change is made.
Press the up or down arrow to increase or decrease the screen brightness.
Four levels are pre-set: Max, Comfortable, Standard (default setting) and
Economy. Press OK when finished.
Note: This can also be called through the brightness icon on the
main display.
For reference, this display gives information on the instrument model,
software version and instrument ID.
board hardware and software.
Pressing the Analog outputs corr. button displays the correction factor that
is applied to the analog outputs.
Pressing the Amplifiers corr. button displays the value of the actual
correction factor on the amplifiers.
For reference this display gives information on the sensor model and type,
last calibration, settings and behavior.