Download Print this page

Heartland Encore Owner's Manual page 16

Advertisement

Clean Room
Once a session time has elapsed, the display will show two solid periods only. This is an indica-
Once a session time has elapsed, the display will show two solid periods only. This is an indica-
tion that the room needs to be cleaned. To clear the clean room indication, press and hold the
Up button on the Heartland Timer in the tanning room until the two period disappear and a "0"
appears. To disable the clean room feature, set parameter 9 to a 0.
Lamp Hours
To check and change Lamp Hours (or any other parameter).
To check and change Lamp Hours (or any other parameter).
TPI ( Third Party Input) Mode
If you are using a FST or Database Series timers, you will need to place the Heartland Timer in
If you are using a FST or Database Series timers, you will need to place the Heartland Timer in
the TPI mode.
the TPI mode.
Connecting the TPI Input
1. Set Parameter 19 to a 1.
1. Set Parameter 19 to a 1.
2. Connect the two actuator wires from the FST or Database timer to the TPI input in the back of
2. Connect the two actuator wires from the FST or Database timer to the TPI input in the back of
the Heartland timer. When a session is started the FST timer will place 5v on these two wires. If
you are using a database Series timer, 24 volts will be applied.
Connecting the TPI output
FST:
1. There are three wires coming from the FST series timer. Two are the actuator wires con-
1. There are three wires coming from the FST series timer. Two are the actuator wires con-
nected to the signal input. Connect the third wire to one of the switch terminals. Make
sure J6 and J7 are on and J4 and J5 are off.
2. Run a jumper from the black actuator wire connected to the other switch screw terminal.
2. Run a jumper from the black actuator wire connected to the other switch screw terminal.
Database:
There are four wires coming from the database series timer. Two are the actuator wires
There are four wires coming from the database series timer. Two are the actuator wires
connected to the signal input. Connect the two other wires to the TPI relay output terminal
J1. Make sure J6, J4 and J5 are off and J7 is on.
Contact closure
If your external timer is simply a relay contact closure, make sure J4, J6, and J5 are on
If your external timer is simply a relay contact closure, make sure J4, J6, and J5 are on
and J7 is off.
Important: J4, J5, and J7 should never be on at the same time!!!
Important: J4, J5, and J7 should never be on at the same time!!!
Operation
When a session is started, voltage will be applied to the TPI input. The display on the Heartland
When a session is started, voltage will be applied to the TPI input. The display on the Heartland
Timer will show the maximum time and count down. When the session ends, the voltage will be
removed from the TPI input and the bed will turn off. Any remaining session time showing on the
Heartland Timer will be eclipsed.
Note:
The Heartland timer can not be used as a stand alone time in the TPI mode.
If the FST or Database Series timers are in delay the Heartland Timer will show a 0. However ,
If the FST or Database Series timers are in delay the Heartland Timer will show a 0. However ,
pressing the Start/Stop button on the Heartland Timer will eclipse the delay time and start the ses-
sion. Pressing the Start/Stop button on the Heartland timer will also clear the clean room indication
on the FST and Database timers.