If the Heartland Timer is being controlled by a T-Max 1A, T-Max 3A, T-Max Manager or T-Max Manager/
Plus, the delay does not need to be set on the Heartland Timer. The delay is controlled by the controlling
device.
1. Press and hold the Start/Stop and Up buttons simultaneously the Heartland Timer until a ".1"
appears on the display. Release the buttons. This should take about 5-6 seconds.
2. Press the Up and Down button until a ".3" is displayed.
3. Press and release the Start/Stop button. A number will appear on the display and be flashing.
A period will be illuminated in the center of the display. This is the current delay time.
4. Press the Up and Down button until the desired delay time is displayed. The highest delay
time that can be set on the Heartland Timer is 10 minutes. If you want no delay time, set the
display to 0. If you set the delay time to 0, the session time will start immediately after the
Start/Stop button is pressed.
5. Press the Start/Stop button. The ".3" will appear on the display. The 3 will not be flashing.
6. To exit, press and hold both the Up and Down buttons until the display shows a "0" with no
periods displayed.
Starting A Session
1. Press the Up and Down button on the Heartland Timer until the desired session time is dis-
played. If the display shows a 0, and you want to count down from the maximum time, press
the down button.
2. Press and release the Start/Stop button to start the session. If a delay other that 0 is entered,
the delay will count down. A period on the lower right corner of the display will flash rapidly.
When the session starts, the period will flash at a once per second rate. If the delay is set to
0, the session will start immediately.
Pausing A Session
To pause the session press the Start/Stop button. The flashing period on the lower right corner
of the display will stop flashing and stay illuminated. To restart, press the Start/Stop button on the
Heartland Timer. The period on the lower right corner of the display will resume flashing.
NOTE: The session time will continue to count down. The display will continue to update and
reflect the remaining session time.
Canceling A Session
To cancel a session. press the Start/Stop button to pause the session then press the Up button.
The display will show a solitary 0.
REMOTE SINGLE BED CONTROL
Remote Single Bed Control is the ability to control a single tanning bed from a remote location. T-
Max 3A at the remote location is required for this configuration.