Frame format programmable dc electronic load
Hide thumbs Also See for IT8500+ Series:

Advertisement

th
4
byte
th
From 5
to 25 byte
th
26
byte
16. Set / Read the list repeat mode. (3CH/3DH)
st
1
byte
nd
2
byte
rd
3
byte
4
th
byte
th
th
From 5
to 25
byte
th
26
byte
17. Set / Read list step counts. (3EH/3FH)
st
1
byte
nd
2
byte
rd
3
byte
th
th
From 4
byte to 5
byte
th
th
From 6
to 25
byte
th
26
byte
18. Set / Read one of the step's current and time values. (40H/41H)
st
1
byte
nd
2
byte
rd
3
byte
th
th
From 4
byte to 5
byte
From 6
th
to 9
th
byte
From 10
th
to 11
th
byte
th
th
From 12
to 25
byte
th
26
byte
19. Save / Recall list file in appointed area.. (4CH/4DH)
st
1
byte
nd
2
byte
rd
3
byte
4
th
byte
th
th
From 5
to 25
byte
th
26
byte
20. Setting / Reading timer value of FOR LOAD ON (50H/51H)
st
1
byte
nd
2
byte
rd
3
byte
LIST operation mode(0 is CC mode)
System reserve
Sum code
Start bit ( AAH )
Address (0—31,0XFF)
Command(3CH/3DH)
LIST repeat operation mode(0 is ONCE, 1 is REPEAT,65535 represents no limit)
System reserve
Sum code
Start bit ( AAH )
Address (0—31,0XFF)
Command(3EH/3FH)
LIST steps count
System reserve
Sum code
Start bit ( AAH )
Address (0—31,0XFF)
Command(40H/41H)
Appointed one step
Current value of current step (Lower bytes are in the front location, higher bytes
are in the later location)
Time value of current step (Lower bytes are in the front location, higher bytes are
in the later location) (1 represent 0.1mS)
System reserve
Sum code
Start bit ( AAH )
Address (0—31,0XFF)
Command(4CH/4DH)
Storing area (1 ~ 7)
System reserve
Sum code
Start bit ( AAH )
Address (0—31,0XFF)
Command(50H/51H)
18