INSTALLATION GUIDE
Version number 1.0 issued March 2001
Aristel Networks Pty Ltd
Unit 3A, 100 Station Street
Nunawading VIC 3161
Telephone: 03 9837 2300
Facsimile:
03 9872 4433
AV 8 Installation Manual
Issued October 2000
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the OMNI AV8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aristel OMNI AV8

  • Page 1 INSTALLATION GUIDE Version number 1.0 issued March 2001 Aristel Networks Pty Ltd Unit 3A, 100 Station Street Nunawading VIC 3161 Telephone: 03 9837 2300 Facsimile: 03 9872 4433 AV 8 Installation Manual Issued October 2000 Page 1...
  • Page 2: Site Requirement

    INTRODUCTION INTRODUCTION This manual provides the detailed procedures for installing the OMNI AV-8 Key Telephone System. Read this entire section before proceeding with the actual installation. Prior to installation carefully inspect all packages for evidence of damage and compare the equipment received against equipment ordered to ensure ALL components have been received.
  • Page 3 FIG 1.1 KSU INSTALLATION LAYOUT DIAG. AV8 Key Switching Unit installation layout Fig 1.1 AV8 KSU Installation layout diagram. AV 8 Installation Manual Issued October 2000 Page 3...
  • Page 4 1. A3PWUB (Power Unit) 5. A3CKCA (1 CO Line & 2 Key Station card) 2. A3MBUA (Mother Board) 5. A3CSCA (1 CO Line & 2 SLTs card) 3. A3CTBA (Terminal Block) 6. A3MFCA (Multi Function card) 4. A3VSCA (Voice Service card) 7.
  • Page 5 A3PWUA Connectors and Test Points GND :Ground Reference Test Point :Test Point for –5V DC output :Test Point for +5V DC output +24V :Test Point for +24V DC output :Connect to AC transformer (240VAC input) :Connect to External Backup Battery connector :Connect to A3MBUA LED 1 :Indicates +5V DC is present when on :Fuse 1, backup battery reverse polarity protection.
  • Page 6 A3MBUA LAYOUT DIAGRAM AV 8 Installation Manual Issued October 2000 Page 6...
  • Page 7 3 Volt Battery Memory backup Battery Connection to Con1 on ASVSC card RSC1 & RSC2 Connection for RSCA card Connection to CON1 on A3MFCA card POWER Connection to J3 on A3PWUA card Connection to CN1 on A3CTBA card Connection to CN3 on A3CTBA card Connection to CN4 on A3CTBA card Connection to CN1 on A3CSCA or A3CKCA cards Connection to CN3 on A3CSCA card...
  • Page 8 A3CTBA LAYOUT DIAG A3CTBA Connectors Connection to CN1 on A3MBUA card Connection to Mains Earth Connection to CN2 on A3MBUA card Connection to CN3 on A3MBUA card Connection to CN2 on A3CKCA or A3CSCA cards J1-J2 Connection to C.O. lines 1-3 and the FAX/PFT J3-J10 Connection to Stations 11-16 and optional Stations/SLTs Connection to External Music source and External PA amplifier AV 8 Installation Manual...
  • Page 9 A3CKCA LAYOUT DIAGRAM Connection to CN4 on A3MBUA card Connection to CN5 on A3CTBA card AV 8 Installation Manual Issued October 2000 Page 9...
  • Page 10 A3CSCA LAYOUT DIAGRAM AV 8 Installation Manual Issued October 2000 Page 10...
  • Page 11 A3VSCA LAYOUT DIAGRAM Time duration for each channel Time duration for each channel is 20 seconds in total is 60 seconds in total AV 8 Installation Manual Issued October 2000 Page 11...
  • Page 12 A2RSCA LAYOUT DIAGRAM AV 8 Installation Manual Issued October 2000 Page 12...
  • Page 13 A3 MFCA LAYOUT DIAGRAM AV 8 Installation Manual Issued October 2000 Page 13...
  • Page 14 * Remove the system front cover. * Use the two notches at the top of the front cover to mark the position on the wall where the unit is to be mounted. * Drive appropriate mounting screws into the wall, according to marked positions. * Suspend the AV8 system on the wall by matching the mounting holes on the back cover to the screws.
  • Page 15 Facsimile Connection The AV 8 system can support a FAX machine connected via the CO3/FAX RJ socket. When using this point for connection, the following should be noted. 1. The RJ connector is a 6P-6C connector using contacts 3 & 4 for the 3 C.O.
  • Page 16 System Back-Up Battery Installation External Cabling Connection: Connect the two wire cable (Male Connector from the Battery Box) to the system Back-Up Battery Female Connector as shown below. External Backup battery installation connection diagram Local Programming Cable The Local Programming Cable is a DB9 to DB9 serial cable that is used when the RSCA card is installed for Local Programming and SMDR data retrieval.
  • Page 17 System, C.O. Line, Key Telephone and Auxiliary Equipment Cabling C. O. Line Connection Where two C. O. Lines are connected to the same socket (eg: C.O.1 & C.O.2), ensure that the polarity of the lines is the same. This will reduce the possibility of tracking and corrosion in humid climates.
  • Page 18 AV 8 Installation Manual Issued October 2000 Page 18...
  • Page 19 The A3MFCA termination provides connection for a Door Station (DOOR), Door Latch (SW) and a Sensor or Alarm input (SENSOR). Only one Door Phone (2 wire) can be connected to the AV8 system. The Relay can be used to operate an electric Door Latch or to operate another device as required.
  • Page 20 Both the External Music source and the External Paging Amplifier MUST be connected through an approved L.I.U. The jumpers JP1 and JP2 must be set for external music if it is to be supplied. The volume control on the Mother Board only controls the Internal Chimes.