Aristel AV-38 Installation Manual

Hide thumbs Also See for AV-38:

Advertisement

CONTENTS
CONTENTS
CONTENTS
CONTENTS
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
SYSTEM INTER-CIRCUIT LAYOUT...................................................................4
A6PWUA (POWER BOARD UNIT).....................................................................5
! A6MBUB MOTHER BOARD UNIT..................................................................6
! A6STU8 8 PORT KEY STATION CARD .........................................................8
! A6HYU 2 KEY & 6 SLT PORT HYBRID STATION CARD ...............................9
! A6SLU 8 SINGLE LINE STATION PORTCARD............................................10
! A6SLC 2 PORT SINGLE LINE STATION CARD,.........................................11
! A6ELC EXPANSION LINK CARD..................................................................11
! A6TKU4 4 PORT TRUNK CARD ..................................................................12
! A6VSC 2 CHANNEL VOICE SERVICE CARD .............................................14
PHONES ..........................................................................................................15
! A6RSC RS232 CARD - 1ST RS232 INTERFACE ........................................16
! A6RPC REMOTE PROGRAMMING CARD ..................................................17
INSTALLATION AND WIRING...................................................................... 18
! AC POWER AND BATTERY BACK-UP INSTALLATION ...............................18
! A6TKU4 AND A6TKU4R TRUNK CARD WIRING - CO LINES, FAX AND
POWER FAIL TELEPHONE TERMINATIONS..................................................19
! METERING PULSE DETECTION CARD INSTALLATION ON A6TKU4R CARDS
ONLY................................................................................................................20
! TELEPHONE STATION WIRING...................................................................21
! EXTERNAL PAGING ANDMUSIC ON HOLD WIRING ..................................31
METERING PULSE DETECTION CARD ........................14
1
2
3
3
4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AV-38 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aristel AV-38

  • Page 1: Table Of Contents

    CONTENTS CONTENTS CONTENTS CONTENTS GENERAL DESCRIPTION GENERAL DESCRIPTION GENERAL DESCRIPTION GENERAL DESCRIPTION INTRODUCTION SPECIFICATION INTRODUCTION SITE REQUIREMENT PCB AND CABINET LAYOUT SYSTEM INTER-CIRCUIT LAYOUT..............4 A6PWUA (POWER BOARD UNIT)..............5 A6RGC RING GENERATOR CARD FOR A6SLU AND A6HYU CARDS ....5 ! A6MBUB MOTHER BOARD UNIT..............6 ! A6STU8 8 PORT KEY STATION CARD ............8 ! A6HYU 2 KEY &...
  • Page 2: Introduction

    INTRODUCTION INTRODUCTION INTRODUCTION ARISTEL AV-38 Telephone System minimum configuration of 4 CO Lines + 8 Stations can be readily expanded to 12 CO Lines + 26 Stations. It is quite versatile and uses: "# IAPX8088 microprocessor for it’s main processing unit.
  • Page 3: Specification

    AV-38 INSTALLATION MANUAL SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS !# GENERAL SPECIFICATION CO Lines 4 ~ 12 DSS64 Consoles 1 max Key Telephones 2 ~ 24 Single Line Telephones 2 ~ 26 Intercom Paths (Local) 1 ~ 9 Power Failure Transfer Phone (PFT)
  • Page 4: Introduction

    INTRODU CTION CTION This manual provides the detailed procedures for installing the ARISTEL AV-38 Key Telephone System. Read this entire section before proceeding with the actual installation. Prior to installation carefully inspect all packages for evidence of damage and compare the equipment received against equipment ordered to ensure ALL components have been received.
  • Page 5: Pcb And Cabinet Layout

    AV-38 INSTALLATION MANUAL PCB AND CABINET LAYOUT PCB AND CABINET LAYOUT PCB AND CABINET LAYOUT PCB AND CABINET LAYOUT !# SYSTEM INTER-CIRCUIT LAYOUT Figure 1. System Inter-Circuit Layout AC Power Inlet. AC Power Switch. Power Indicator (LED Type). DC Power Switch.
  • Page 6: A6Pwua (Power Board Unit)

    !#A6RGC RING GENERATOR CARD FOR A6SLU and A6HYU CARDS Figure 3. A6RGC (Ring Generator Card) CN901 : 4-Wire Connector. Connect to [CN802] on the A6PWUA. CN902 : 2-Wire Connector. Connect to [RING] the A6MBUB. AV-38 INSTALLATION MANUAL Issued March 2001...
  • Page 7: A6Mbub Mother Board Unit

    AV-38 INSTALLATION MANUAL !# A6MBUB MOTHER BOARD UNIT Figure 4. A6MBUB (Mother Board Unit) AV-38 INSTALLATION MANUAL...
  • Page 8 : Factory Use Only 30. VSC : Connector for the A6VSC. 31. U3 : System Software EEPROM. 32. CON1 : EH64 connector. 33. CON2 : Same as [CON1]. 34. SLCP : Power connector for SLC card. AV-38 INSTALLATION MANUAL Issued March 2001...
  • Page 9: A6Stu8 8 Port Key Station Card

    AV-38 INSTALLATION MANUAL A6STU8 8 PORT KEY STATION CARD : Amp Connector for Key Station Wiring CON4 : Connector for the A6ELC when the THIRD Trunk Unit is installed. : 12-Wire Connector Cable. Connect to [STU] position on A6MBUB. : 62-Wire Connector Cable. Connect to [STA] position on A6MBUB.
  • Page 10: A6Hyu 2 Key & 6 Slt Port Hybrid Station Card

    : 12-Wire Connector Cable. Connect to [STU] position on A6MBUB. : 62-Wire Connector Cable. Connect to [STA] position on A6MBUB. : 4-Wire Connector to [PWR] position on A6MBUB. CON3 : Same as [CON4], but connect to [CON3] position on A6ELC. AV-38 INSTALLATION MANUAL Issued March 2001...
  • Page 11: A6Slu 8 Single Line Station Portcard

    AV-38 INSTALLATION MANUAL !# A6SLU 8 SINGLE LINE STATION PORTCARD Figure 7. A6SLU 8 Port Single Line Station Card : 25-Pairs Amp connector used for SLT wiring. CON4 : Connector for the A6ELC when the THIRD Trunk Unit is installed.
  • Page 12: A6Slc 2 Port Single Line Station Card

    A6ELC CARDS MUST BE INSTALLED ON ALL 8 PORT STATION CARDS AND THE A6MBUB WHEN THE THIRD TRUNK CARD IS INSTALLED. ALSO, ALL 4 SWITCHES (SW2) ON THE A6MBUB MUST BE TURNED OFF. AV-38 INSTALLATION MANUAL Issued March 2001 1-11...
  • Page 13: A6Tku4 4 Port Trunk Card

    AV-38 INSTALLATION MANUAL !# A6TKU4 4 PORT TRUNK CARD Figure 10. A6TKU4 4 Port Trunk Card CON2 : Dual RJ11-6P6C Connector. For the connection of FAX Machine and Power Failure Transfer Phones (PFT). FAXM : For the FAX Machine Connection, it is paralleled with the 4th CO Line Port and worked as FAX MONITOR function.
  • Page 14: A6Tku4R 4 Port Trunks Card With Reversal & Metering

    : Connect to [CN2] position on A6MDC12 for [CO1]. CN1B : Connect to [CN1] position on A6MDC12 for [CO2]. CN2B : Connect to [CN2] position on A6MDC12 for [CO2]. : Connect to [TKU] position on A6MBUB. AV-38 INSTALLATION MANUAL Issued March 2001 1-13...
  • Page 15: A6Mdc12 12Kh Zmetering Pulse Detection Card

    AV-38 INSTALLATION MANUAL !# A6MDC12 12KHz METERING PULSE DETECTION CARD A6MDCA Figure 12. A6MDC12 12KHz Metering Pulse Detection Card : Connect to [CN2 (A~D)] position on A6TKU4R. : Connect to [CN1 (A~D)] position on A6TKU4R. !# A6VSC 2 CHANNEL VOICE SERVICE CARD Figure 13.
  • Page 16: A6Mfc Multi Function Card, 2 Sensors + 2 Relays + 2 Door

    Figure 14. A6MFC Multi Function Card, 2 Sensors+2 Relays+2 Door Phones SW1 & 2 : Connectors for the relays. SEN1 & 2 : Connectors for the sensors. DOOR1 & 2 : Connectors for the door stations. : Connect to [MFC] position on A6MBUA. AV-38 INSTALLATION MANUAL Issued March 2001 1-15...
  • Page 17: A6Rsc Rs232 Card - 1St Rs232 Interface

    AV-38 INSTALLATION MANUAL !# A6RSC RS232 CARD - 1ST RS232 INTERFACE Figure 15. A6RSC RS232 Card CN : Connector for the cable and DB9 socket to the main equipment housing. PC Connected Printer Connected Tx - to PC Rx - from Printer...
  • Page 18: A6Rscb 2 Nd Rs232 Interface Card

    RS232 output must be set to send SMDR to correct RS232 port (Default RS232 1) !# A6RPC REMOTE PROGRAMMING CARD Figure 17. A6RPC Remote Programming Card : Connect to [RPC] position on A6MBUB. AV-38 INSTALLATION MANUAL Issued March 2001 1-17...
  • Page 19: Installation And Wiring

    AV-38 INSTALLATION MANUAL INSTALLATION AND WIRING INSTALLATION AND WIRING INSTALLATION AND WIRING INSTALLATION AND WIRING !# AC POWER AND BATTERY BACK-UP INSTALLATION Figure 18. AC Power and DC Battery Back-Up Installation CAUTION There are Hazardous voltages present in the Power Supply.
  • Page 20: Power Fail Telephone Terminations

    CO12 CO10 PFT1 and PFT2 can be wired as Power Failure Transfer Phones across CO1 & CO2 of each A6TKU4 and A6TKU4R card. Power Failure Transfer Phone MUST be analogue Single Line Telephones. AV-38 INSTALLATION MANUAL Issued March 2001 1-19...
  • Page 21: Metering Pulse Detection Card Installation On A6Tku4R Cards Only

    AV-38 INSTALLATION MANUAL !# METERING PULSE DETECTION CARD INSTALLATION ON A6TKU4R CARDS ONLY Figure 20. Metering Pulse Detection Card Installation Up to four A6MDC12 cards can be installed in each A6TKU4R card. One A6MDC12 card is required for each CO Line provided with meter pulses.
  • Page 22: Telephone Station Wiring

    AV-38 INSTALLATION MANUAL !# TELEPHONE STATION WIRING A. ON A6STU Figure 21. Key Station Wiring on A6STU AV-38 INSTALLATION MANUAL Issued March 2001 1-21...
  • Page 23 AV-38 INSTALLATION MANUAL AT/AR is the audio pair; AT = Transmission (Green Color), AR = Receiving (Red Color). BT/BR is the Data/Power pair; BT = (-) Pole and Data Receiving (Black Color), BR = (+) Pole and Data Transmission (Yellow Color).
  • Page 24 AV-38 INSTALLATION MANUAL ON A6HYU Figure 22. Key Station Wiring on A6HYU AV-38 INSTALLATION MANUAL Issued March 2001 1-23...
  • Page 25 AV-38 INSTALLATION MANUAL Only the FIRST TWO Station Ports on A6HYU can be connected with Key Telephone. AT/AR is the audio pair; AT = Transmission (Green Color), AR = Receiving (Red Color). BT/BR is the Data/Power pair; BT = (-) Pole and Data Receiving (Black Color), BR = (+) Pole and Data Transmission (Yellow Color).
  • Page 26: Ohca Key Station Installation Only Available On A6Stu

    AV-38 INSTALLATION MANUAL !# OHCA KEY STATION INSTALLATION ONLY AVAILABLE ON A6STU Figure 23. OHCA Key Telephone Wiring on A6STU AV-38 INSTALLATION MANUAL Issued March 2001 1-25...
  • Page 27 AV-38 INSTALLATION MANUAL The Key Telephone for OHCA application must contain a HANDSFREE card. OHCA installation is only available on A6STU. The EIGHTH Key Station Port as [KP ST8] MUST be sacrificed to release its Audio Path for the OHCA application on other Key Station Ports.
  • Page 28 AV-38 INSTALLATION MANUAL C. ON A6SLU Figure 24. SLT Station Wiring on A6SLU AV-38 INSTALLATION MANUAL Issued March 2001 1-27...
  • Page 29 AV-38 INSTALLATION MANUAL [SLT ST1] ~ [SLT ST8] can connect with Single Line Telephone. Wiring Table of 25-Pairs Amphonel Cable Pin No. Status Function ST Port Pin No. Status Function ST Port SLT ST1 SLT ST5 Audio Pair Audio Pair...
  • Page 30 Connect SLC cable from [CN1] position on A6SLC to the System Case. There are two SLT ports. A6SLC provides two SLT ports. SLT1 (Pins 3&4) and SLT2 (Pin 1&6) can be connected with Single Line Telephones. AV-38 INSTALLATION MANUAL Issued March 2001 1-29...
  • Page 31: A6Mfc Installation Of The Door Phone, Sensor And Switch

    AV-38 INSTALLATION MANUAL !# A6MFC Installation of the DOOR PHONE, SENSOR and SWITCH wiring. ALARM or DOOR PHONE DOOR LATCH DOOR SENSOR SELV Power Supply DOOR 1 DOOR 2 SEN 1 SEN 2 SW 1 SW 2 Figure 26. 2-Wire Door Phone Connection on A6MFC A6MFC provides two connections of Door Phone Device, two sensors contacts and can operate two door latches or relays.
  • Page 32: External Paging Andmusic On Hold Wiring

    Back Ground Music and/or Music On Hold by Jumper Selection on A6MBUB. External Paging 3. Connect 2-conductor wiring cord from External Paging Equipment to [EXT. PAGE] on A6MBUB using an approved Line Isolation Unit (LIU). AV-38 INSTALLATION MANUAL Issued March 2001 1-31...
  • Page 33: Rs232 (Serial Printer Or Pc) And Rpc Installation

    AV-38 INSTALLATION MANUAL !# RS232 (SERIAL PRINTER OR PC) and RPC INSTALLATION 1-32 AV-38 INSTALLATION MANUAL...
  • Page 34 Connect the cable from [CN] position on A6RSCA (or A6RSCB) to the System Case. Setup the Jumper Selection on A6RSC (or A6RSCB) according to the connection terminal is either PC or Serial Printer. REMOTE PROGRAMMING CARD install A6RPC to [RPC] position on A6MBUB AV-38 INSTALLATION MANUAL Issued March 2001 1-33...

Table of Contents