Specifications And Requirements; Safety Information - Tyco iSTAR Ultra G2 SE Quick Start Manual

Table of Contents

Advertisement

Specifications and Requirements

Specifications
Environmental
Operational Temperature
Electrical (GCM)
Electrical Input
Electrical (ACM-SE)
VIN
Electrical Input
RS485
Electrical Output
Wiegand
Electrical Output
Relay Ports (Dry - Primary)
Electrical Output
Voltage tolerances are 85% - 100% of listed specifications.
NOTE

Safety Information

Life Safety Requirement
• A fail-safe mechanism override must be installed at each card reader exit to allow people to leave the secure area in case of
electromechanical device failure.
• Disconnect all power before modifying any jumper settings or the wiring to, or within, the iSTAR Ultra G2 SE.
Table 1:  Environmental and Electrical Specifications
iSTAR Ultra G2 SE Specifications
32° F (0° C) to 120° F (49° C)
12 VDC (3 A) or 24 VDC (1.5 A)
Up to 12 VDC (9 A) or 24 VDC (3 A)
12 VDC (1.2 A) per port.
12 VDC (0.8 A) per port.
Primary: 30 V AC/DC (5 A maximum)
3