Cleaning The Cooling Fins And The Cooling Air Intake Openings - Fayat Group BOMAG BP 10/35 Service Manual

Table of Contents

Advertisement

Machine assemblies – Engine
Assembling the air filter
Fig. 51

4.1.5 Cleaning the cooling fins and the cooling air intake openings

76
BP 10/35 / BP 12/40 / BP 12/50 / BVP 10/36 / BVP 12/50 / BVP 18/45
NOTICE!
Danger of engine damage!
Insert the filter element correctly.
15.
Install the rubber seal (5).
16.
Insert the filter element (4) correctly and tighten it with the
wing nut (3).
17.
Reassemble the air filter cover (2) with the wing nut (1).
How dirty the cooling fins and cooling air intake
openings are depends very much on the daily
operating conditions; clean daily if necessary.
NOTICE!
Danger of engine damage caused by reduced
cooling!
For this reason you should always seal any oil
or fuel leaks in the vicinity of the cooling fan or
the coolers and clean the cooling fins after.
Protective equipment:
n
n
n
1.
Park the machine in secured condition
„Parking the machine in secured condition" on page 41.
2.
Allow the engine to cool down.
Working clothes
Protective gloves
Safety goggles
Ä Chapter 1.3.3