7.3.4

General firing tips

The appliance works best when it has heated up as described in section 7.3.1.
Insufficient heating up leads to a low chimney draught, black deposits on the glass
and incomplete combustion. Good combustion is recognized by bright orange flames,
invisible smoke and no soot deposits on the glass. Use the control lever to get good
combustion. Refer to section
Make sure the door of the appliance is closed when in use. Only open the door for
ignition and to refuel.
Do not remove all the ashes. An ash layer in the combustion chamber forms a heat
insulating layer, that helps the fuel to ignite easy.
Do not set the control lever in the far left position (all combustion air inlets closed)
when the appliance is used. This will cause severe smoke development, soot
formation and increases the chance of a chimney fire.
After the first load, do not overload the appliance with fuel. Refer to section
the recommended amount of fuel. Too much fuel leads to incomplete combustion, soot
formation and a chance of a chimney fire.
7.4
Firing the appliance with the optional Barbas Opti-Air
system
If the appliance has the optional Opti-Air system, the appliance automatically controls the
amount of combustion air. With the Barbas Opti-Air app for Android and iOS it is possible
to select from 5 different combustion levels or to select room temperature control.
Refer to section
7.4.1

Installation of the Opti-Air app

1.
2.
3.
4.
5.
6.
7.4.2

First load and ignition with Opti-Air

During operation, the Opti-Air system only works with closed door. Only open the door for
a short time for ignition and reloading with fuel.
Cuatro-7 75-60
Caution:
Continuous firing with the primary air inlet fully open (control lever in the far
right position) causes a white-hot fire that can damage the appliance. Use the
primary air only during the first fuel load and for ignition of a new fuel load.
4.2
fro a detailed description of the Opti-Air system.
Download the Barbas Opti-Air app from Google Play (Android) or the App Store
(iOS) and install it on your mobile phone or tablet.
Start the Barbas Opti-Air on your mobile device.
Make sure bluetooth is on and can recognize other devices.
Start to make a connection with bluetooth with device Airmaster.
When asked, enter the PIN code 000000.
The app is now ready for use.
Note: It is possible to install the Barbas Opti-Air app on multiple mobile
devices. However, the app can only be active on 1 mobile device at the same
time. Before making connection between the appliance and a second mobile
device, disconnect the bluetooth connection between the appliance and the
first mobile device.
6.1
for advice on the required fuel quality.