Fuel Amount (With Opti-Air) - barbas Cuatro-7 75-60 User Manual

Hide thumbs Also See for Cuatro-7 75-60:
Table of Contents

Advertisement

Fuel
6.2.2

Fuel amount (with Opti-Air)

It is recommended to load the appliance with the amount of fuel as listed in the tables
hereunder. Put the load as one layer on the floor of the combustion chamber. For the
amount of fuel for the first load see section
Combustion
(appliance
has a con-
vection venti-
Combustion
(appliance
does not
have a con-
vection venti-
Use wood logs or wood briquettes (without binder) with a length of approximately 30 cm
and an outline of approximately 25 cm.
The above listed amount burns for approximately 45 minutes. This time can be different,
dependent on the chimney draught and the position of the combustion air valve.
16
Caution:
The amount of fuel specified here should not be exceeded, overloading can
cause excess smoke.
level
Thermal output
lator)
1
Minimum
2
Minimum
3
Nominal
4
Nominal
5
Maximum
level
Thermal output
lator
1
Minimum
2
Nominal
3
Maximum
7.4.2
.
Number of wood logs /
wood briquettes
2
2
3
3
3
Number of wood logs /
wood briquettes
2
3
3
Weight
wood logs: approx 1.0 kg
per piece
wood briquettes: approx
0.8 kg per piece
Weight
wood logs: approx 1.0 kg
per piece
wood briquettes: approx
0.8 kg per piece