9.6
Coolant Flushing
(1) Introduction
Coolant Flushing is able regardless of tools and materials, and serves to kick the chips
slide cover.
And line. 2-axis, M device is a option
(2) Coolant Flushing operation
Coolant Flushing is capable of only automatic operation using the M-code.
M138 : Coolant Flushing, Bed shower coolant "ON"
M139 : Coolant Flushing, Bed shower coolant "OFF"
1) When you command the M138, Option coolant motor works.
2) When you command the M139, Coolant Flushing will stop.
In addition to the M-code above, Coolant Flushing also stop the following cases.
- Emergency stop.
- Press the NC RESET switch of MCP.
- Commanded the M02/M03.
- Commanded the M00/M01.
(Coolant that were stopped in the M00/M01 directive is to be resumed back to the
basic operation to resume automatically.)